A novel adsorbent of magnetic graphene oxide (GO) chemically modified by cysteamine hydrochloride (Fe3O4@SiO2/GO-NH2) through thiol-ene click chemistry reaction was synthesized. The prepared Fe3O4@SiO2/GO-NH2 exhibit selective adsorption to As(V) with high adsorption capacity (52.66 mg g(-1)). Taking Fe3O4@SiO2/GO-NH2 as the adsorbents, a new method of magnetic solid phase extraction (MSPE) combined with graphite furnace atomic absorption spectrometry (GFAAS) was developed in determining trace-level inorganic arsenic species (As(III) and As(V)) in environmental water and bottled water samples. Various experimental parameters affecting the MSPE have been optimized. Under the optimal experimental parameters, the limit of detection of the established method for As(V) was 1.02 ng L-1, the relative standard deviations were 7.9% (intraday, c = 50 ng L-1, n = 5) and 4.6% (inter-day, c = 50 ng L-1, n = 7), respectively, and the enrichment factor of the method was 392. GBW08666 and GBW08667 (certified reference material) were analyzed to confirm the accuracy of the method, and the results were matched well with the certified values. The established MSPE-GFAAS method was successfully applied in analyzing trace/ultratrace As(III) and As(V) in real water samples.
机译:盐酸半胱胺化学改性磁性氧化石墨烯吸附剂(Fe3O4@SiO2/通过硫醇-烯点击化学反应合成了GO-NH2。准备好的Fe3O4@SiO2/GO-NH2对As(V)有选择性吸附,吸附容量高(52.66 mg g(-1))。拿Fe3O4@SiO2/以GO-NH2为吸附剂,建立了磁性固相萃取(MSPE)结合石墨炉原子吸收光谱(GFAAS)测定环境水样和瓶装水中痕量无机砷(as(III)和as(V))的新方法。对影响MSPE的各种实验参数进行了优化。在最佳实验参数下,所建立的As(V)检测方法的检出限为1.02 ng L-1,相对标准偏差分别为7.9%(日内,c=50 ng L-1,n=5)和4.6%(日间,c=50 ng L-1,n=7),该方法的富集因子为392。对GBW08666和GBW08667(标准物质)进行分析,以确认方法的准确性,结果与标准值吻合良好。所建立的MSPE-GFAAS方法已成功应用于实际水样中痕量/超痕量As(III)和As(V)的分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号