首页> 外文期刊>Electrophoresis: The Official Journal of the International Electrophoresis Society >Separation and determination of alkyl sulfate surfactants in wastewater by capillary electrophoresis coupled with contactless conductivity detection after preconcentration by simultaneous adsorption using alumina beads
【24h】

Separation and determination of alkyl sulfate surfactants in wastewater by capillary electrophoresis coupled with contactless conductivity detection after preconcentration by simultaneous adsorption using alumina beads

机译:用氧化铝珠子同时吸附在预浓缩后毛细管电泳分离和测定废水中的烷基硫酸盐表面活性剂

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The aim of the present study is to determine four anionic alkyl sulfate (AS) surfactants with different alkyl chains, namely, C8, C10, C12, and C14, in wastewater by CE with capacitively coupled contactless conductivity detection (CE-(CD)-D-4). The conditions effective for the separation of the four AS surfactants were systematically optimized and found to be in a Tris-His (50 mM/20 mM) BGE solution at a pH of 8.95, using a separation voltage of +15 kV, hydrodynamic injection by siphoning using a 20 cm injection height and an injection time of 20 s. The LODs for C8, C10, C12, and C14 were 2.58, 2.30, 2.08, and 3.16 mg/L, respectively. The conditions used to achieve the simultaneous adsorption and preconcentration of the AS surfactants using Al(2)O(3)beads were pH of 3 and 0.1 mM NaCl. The adsorption efficiencies were found to be 45.6, 50.8, 81.7, and 99.9%, while the desorption efficiencies reached 66.1, 70.4, 83.9, and 100.0% for C8, C10, C12, and C14, respectively. The concentrations of the AS surfactants in wastewater samples were quantified by CE-(CD)-D-4 after preconcentration by simultaneous adsorption using Al(2)O(3)beads. The results obtained from the proposed method were consistent with those obtained by HPLC-MS/MS, with a deviation of less than 15%. Our results indicate that the CE-(CD)-D-4 performed after preconcentration by an adsorption technique using Al(2)O(3)beads is a new, inexpensive, and suitable method for quantifying AS surfactants in wastewater samples.
机译:本研究的目的是通过电容耦合非接触电导检测(CE-(CD)-D-4)测定废水中四种不同烷基链的阴离子烷基硫酸盐(AS)表面活性剂,即C8、C10、C12和C14。对分离四种AS表面活性剂的有效条件进行了系统优化,发现其在pH值为8.95的Tris-His(50 mM/20 mM)BGE溶液中,使用+15 kV的分离电压,通过虹吸进行流体动力注射,使用20 cm的注射高度和20 s的注射时间。C8、C10、C12和C14的LOD分别为2.58、2.30、2.08和3.16 mg/L。使用Al(2)O(3)珠实现AS表面活性剂同时吸附和预浓缩的条件为pH值为3和0.1 mM NaCl。C8、C10、C12和C14的吸附效率分别为45.6%、50.8%、81.7%和99.9%,而解吸效率分别达到66.1%、70.4%、83.9%和100.0%。用Al(2)O(3)微球同时吸附富集后,用CE-(CD)-D-4定量测定废水样品中AS表面活性剂的浓度。该方法所得结果与HPLC-MS/MS法所得结果一致,偏差小于15%。我们的结果表明,通过使用Al(2)O(3)珠的吸附技术预富集后进行的CE-(CD)-D-4是一种新的、廉价的、适用于废水样品中表面活性剂定量的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号