This article conducts optimization and sensitivity analysis for the cold-end system of a nuclear power plant (NPP) with a sea water circulating system, using the minimum annual cost method by dynamic economical analysis. The following factors are taken into account for the optimization: the design of a condenser (cooling area and the parameters of cooling tubes), the scale of the cooling tower, the flow rate of circulation water, and the diameter of circulating pipes. In conclusion, the optimum scheme of the cold-end system is obtained for the double-back pressure turbine project. The variation trend of the annual cost with changing circulating water amount is also concluded. Finally, this article provides the sensitivity analysis of the feed-in tariff.
机译:本文采用最小年费用法,通过动态经济性分析,对一座核电厂(NPP)海水循环系统的冷端系统进行了优化和灵敏度分析。优化时考虑了以下因素:冷凝器的设计(冷却面积和冷却管的参数)、冷却塔的规模、循环水的流量和循环管的直径。综上所述,得出了双背压汽轮机冷端系统的优化方案。得出了年费用随循环水量变化的趋势。最后,本文对上网电价进行了敏感性分析。