Corrosion rate of mild steel in tap water during 4300 h was estimated by LPR and weight-loss methods coupled with OCP measurements. The LPR results were found to be overestimated compared to the weight-loss data within initial 2000 h of exposure. The electrochemical activity of the rust separated from the metal surface was studied by cycling voltammetry using a home-built powder graphite electrode. High redox currents corresponding to the initial 2000 h of exposure were detected. Rust composition was characterized with IR and XRD, and the highest amounts of electrochemically active beta- and gamma-FeOOH were again detected for the initial 2000 h. Current consumption in rust transformation processes during LPR measurement in the galvanostatic mode accounts for overestimation of the corrosion rate. The time dependence of rust electrochemical activity correlates with OCP variation with time. During initial 2000 h, OCP values are shifted by 50 mV to cathodic side. For the period of a higher rust electrochemical activity, the use of a reduced B is suggested to increase accuracy of LPR technique in tap water.
机译:采用LPR和失重法,结合OCP测量,估算了低碳钢在自来水中4300h的腐蚀速率。与最初接触2000小时内的减肥数据相比,LPR结果被高估。利用自制的粉末石墨电极,通过循环伏安法研究了从金属表面分离的锈迹的电化学活性。检测到与最初2000小时暴露相对应的高氧化还原电流。用IR和XRD对铁锈成分进行了表征,并在最初的2000小时内再次检测到最高数量的电化学活性β-和γ-FeOOH。恒电流模式下LPR测量期间铁锈转化过程中的电流消耗导致腐蚀速率被高估。铁锈电化学活性的时间依赖性与OCP随时间的变化有关。在最初的2000小时内,OCP值向阴极侧移动50 mV。对于锈蚀电化学活性较高的时期,建议使用还原B,以提高自来水中LPR技术的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号