首页> 外文期刊>Animal Feed Science and Technology >Instantaneous determination of crude proteins, fat and fibre in animal feeds using near infrared reflectance spectroscopy technology and a remote reflectance fibre-optic probe.
【24h】

Instantaneous determination of crude proteins, fat and fibre in animal feeds using near infrared reflectance spectroscopy technology and a remote reflectance fibre-optic probe.

机译:使用近红外反射光谱技术和远程反射光纤探头可立即测定动物饲料中的粗蛋白,脂肪和纤维。

获取原文
获取原文并翻译 | 示例
           

摘要

In the present study we address the development of a rapid technique - near infrared reflectance spectroscopy (NIRS) technology and the use of a remote reflectance crude fibre (CF)-optic probe (fitted with a 5 cm x 5 cm quartz window) - to perform instantaneous analysis of quantitative parameters such as the ether extract (DM), crude protein (CP) and crude fibre in animal feed and fodder. The technique does not involve the destruction or treatment of the sample because it is based on direct application of a fibre-optic probe on the feed (with different physical characteristics, such as commercialisation in the form of meal, tablets and granules) given to cattle, swine, sheep, birds and rabbits that is used in different stages of animal development - juvenile development, growth, fattening, etc. The regression method employed was modified partial least squares (MPLS). The calibration results using 72 samples permitted the determination of crude protein, the ether extract and crude fibre. This calibration is applicable within the ranges for crude protein of 5-495 g kg-1; the ether extract, 16-66 g kg-1; crude fibre, 23-111 g kg-1, with multiple correlation coefficients (RSQ) for crude protein, the ether extract and crude fibre of 0.991, 0.932 and 0.848, respectively. The standard errors of prediction corrected (SEPC) for the above parameters in g kg-1 were 12.5, 2.09 and 6.05, respectively. The robustness of the analytical method was confirmed by applying it to 10 samples for external validation. The results obtained indicate that NIRS with a fibre-optic probe can be used as a quality control method in animal feeds and fodder for the determination of crude protein, the ether extract and crude fibre..
机译:在本研究中,我们着眼于快速技术的发展-近红外反射光谱(NIRS)技术以及使用远程反射粗纤维(CF)-光学探头(装有5 cm x 5 cm石英窗)的问题。对动物饲料和饲料中的醚提取物(DM),粗蛋白(CP)和粗纤维等定量参数进行即时分析。该技术不涉及样品的破坏或处理,因为它是基于将光纤探针直接应用于牛身上的饲料(具有不同的物理特性,例如以粉,片剂和颗粒形式的商品化)而制成的。 ,猪,绵羊,鸟类和兔子,它们用于动物发育的不同阶段-幼年发育,生长,育肥等。采用的回归方法是修正的偏最小二乘(MPLS)。使用72个样品的校准结果可以测定粗蛋白,乙醚提取物和粗纤维。该校准适用于5-495 g kg-1的粗蛋白范围;醚提取物,16-66 g kg-1;粗纤维23-111 g kg-1,粗蛋白,醚提取物和粗纤维的多重相关系数(RSQ)分别为0.991、0.932和0.848。上述参数在g kg-1中的预测校正标准误差(SEPC)分别为12.5、2.09和6.05。通过将其应用于10个样品进行外部验证,证实了该分析方法的鲁棒性。获得的结果表明,带有纤维探针的近红外光谱仪可以用作动物饲料和饲料中的质量控制方法,用于测定粗蛋白,醚提取物和粗纤维。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号