In the community setting, assessing spirometry in school-aged children is often limited by the unavailability of respirology technicians at the point-of-care. We developed a new technique called the Rapid Expiratory Occlusion Method (REOM) that measures respiratory resistance during normal breathing, without specialized training. The aim was to examine the concordance between respiratory resistance measured with the REOM and respiratory resistance measured by oscillometry on the tremoflo. Children aged 6-17yr, with or without asthma, received respiratory resistance testing on the tremoflo, then on the REOM. Three to five replicates with a coefficient of variation <= 15% were obtained on each instrument; the primary outcome was the concordance between the average respiratory resistance on the REOM and that measured at 5 Hz (R-5) on the tremoflo. Thirty-two children (11 girls; 21 boys) were enrolled with a mean age of 11.2 (range 6-17) yr; after excluding two children not meeting reproducibility criteria, 9 healthy controls, 15 controlled asthmatics, and 6 poorly controlled asthmatics were included. Resistance measured on the REOM showed a strong correlation with R-5 measured on the tremoflo (P < 0.0001) with no significant differences on the Bland-Altman analyses. Children and their parents found the REOM easy to use and would consider for home use if recommended by their doctor. With the high concordance between resistance values measured on the REOM and that on the tremoflo combined with perceived ease of use, the REOM appears as a promising means for measuring lung function, thus supporting further testing of other psychometric properties.
机译:在社区环境中,评估学龄儿童的肺活量通常受到护理点呼吸技术人员不可用的限制。我们开发了一种称为快速呼气阻塞法(REOM)的新技术,可以在正常呼吸时测量呼吸阻力,无需专门训练。目的是检验REOM测量的呼吸阻力与tremoflo示波器测量的呼吸阻力之间的一致性。6-17岁的儿童,无论是否患有哮喘,都在tremoflo上接受了呼吸阻力测试,然后在REOM上进行了测试。在每个仪器上获得变异系数小于等于15%的三到五个重复;主要结果是REOM的平均呼吸阻力与tremoflo在5 Hz(R-5)下测得的平均呼吸阻力之间的一致性。32名儿童(11名女孩;21名男孩)被纳入研究,平均年龄为11.2岁(6-17岁);排除两名不符合再现性标准的儿童后,纳入9名健康对照组、15名哮喘控制组和6名哮喘控制不良组。在REOM上测得的抗性与在tremoflo上测得的R-5有很强的相关性(P<0.0001),而在Bland Altman分析中没有显著差异。孩子们和他们的父母发现,使用方便,如果他们的医生推荐,他们会考虑使用家用。REOM测量的阻力值与tremoflo测量的阻力值高度一致,再加上易于使用的感觉,REOM似乎是测量肺功能的一种有希望的方法,从而支持对其他心理测量特性的进一步测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号