首页> 外文期刊>Magma: Magnetic resonance materials in physics, biology, and medicine >Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T
【24h】

Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T

机译:单次呼吸饱和恢复3D心脏T1通过3T的压缩意义映射

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives To propose and validate a novel imaging sequence that uses a single breath-hold whole-heart 3D T1 saturation recovery compressed SENSE rapid acquisition (SACORA) at 3T.Methods The proposed sequence combines flexible saturation time sampling,compressed SENSE,and sharing of saturation pulses between two readouts acquired at different RR intervals.The sequence was compared with a 3D saturation recovery single-shot acquisition (SASHA) implementation with phantom and in vivo experiments (pre and post contrast;7 pigs) and was validated against the reference inversion recovery spin echo (IR-SE) sequence in phantom experiments.Results Phantom experiments showed that the T1 maps acquired by 3D SACORA and 3D SASHA agree well with IR-SE.In vivo experiments showed that the pre-contrast and post-contrast T1 maps acquired by 3D SACORA are comparable to the corresponding 3D SASHA maps,despite the shorter acquisition time (15s vs.188s,for a heart rate of 60 bpm).Mean septal pre-contrast T1 was 1453 ± 44 ms with 3D SACORA and 1460 ± 60 ms with 3D SASHA.Mean septal post-contrast T1 was 824 ± 66 ms and 824 ± 60 ms.Conclusion 3D SACORA acquires 3D T1 maps in 15 heart beats (heart rate,60 bpm) at 3T.In addition to its short acquisition time,the sequence achieves good T1 estimation precision and accuracy.
机译:目的提出并验证一种新的成像序列,该序列使用3T单次屏气全心3D T1饱和恢复压缩感知快速采集(SACORA)。方法该序列结合了灵活的饱和时间采样、压缩感知和在不同RR间隔获取的两个读数之间共享饱和脉冲。将该序列与3D饱和恢复单次激发采集(SASHA)实施的体模和活体实验(对比前后;7头猪)进行比较,并在体模实验中对照参考反转恢复自旋回波(IR-SE)序列进行验证。结果体模实验表明,3D SACORA和3D SASHA获得的T1图谱与IR-SE一致。体内实验表明,3D SACORA获得的对比前和对比后T1图与相应的3D SASHA图具有可比性,尽管采集时间较短(对于60 bpm的心率,分别为15秒和188秒)。3D SACORA和3D SASHA的平均间隔造影前T1分别为1453±44 ms和1460±60 ms。平均间隔造影后T1为824±66ms和824±60ms。结论3D SACORA获得了3T时15次心跳(心率60bpm)的3D T1图。除了捕获时间短之外,该序列还获得了良好的T1估计精度和准确度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号