The automated analysis of bone marrow aspirates was performed to estimate the bone marrow cellularity and differential cell count. Total nucleated cell count (TNC) was measured using an automated hematology analyzer. TNC of the bone marrow correlated well with the bone marrow cellularity estimated by microscopic examination (r = 0.590, p <0.001). The bone marrow cellularity was readily confirmed as <30%, from 30 to 70%, or >70% according to TNC. Differential count of bone marrow cells was done with the combination of CD45 monoclonal antibody and propidium iodide using flow cytometry. Excellent correlations were obtained for the population distributions of normoblasts, eosinophils, lymphocytes, and blasts between the results of flow cytometry and manual differential counts. The percentage of mature granulocytes in flow cytometry showed good correlation with the manual percentage of metamyelocytes + neutrophils. The percentage of immature granulocytes by flow cytometry showed good correlation with the manual percentage of blasts + promyelocytes + myelocytes. These results demonstrate that analysis of bone marrow aspirates using an automated hematology analyzer is valuable in the determination of bone marrow cellularity. Moreover, as flow cytometry provides objective findings for percentages of major cell populations, it can serve as a method to automate bone marrow differentials.
机译:进行了骨髓抽吸物的自动分析,以估计骨髓的细胞密度和细胞计数。使用自动血液分析仪测量总有核细胞计数(TNC)。骨髓的TNC与通过显微镜检查估计的骨髓细胞具有很好的相关性(r = 0.590,p <0.001)。根据TNC,很容易确认骨髓细胞率是<30%,30%至70%或> 70%。使用流式细胞术结合CD45单克隆抗体和碘化丙啶对骨髓细胞进行差异计数。流式细胞仪检测结果与人工差异计数之间的正常母细胞,嗜酸性粒细胞,淋巴细胞和母细胞的种群分布具有极好的相关性。流式细胞术中成熟粒细胞的百分比与间质粒细胞+中性粒细胞的手动百分比显示出良好的相关性。流式细胞仪检测未成熟粒细胞的百分比与原始细胞的原始百分率+早幼粒细胞+骨髓细胞的百分比显示出良好的相关性。这些结果表明,使用自动血液分析仪对骨髓抽吸物进行分析对于确定骨髓细胞的数量非常有价值。此外,由于流式细胞术提供了主要细胞群百分比的客观发现,因此它可以作为自动化骨髓分化的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号