首页> 外文期刊>The International journal of periodontics & restorative dentistry >Effect of Cervical Collar Removal on the Fracture Load of Anterior Zirconia Crowns
【24h】

Effect of Cervical Collar Removal on the Fracture Load of Anterior Zirconia Crowns

机译:宫颈套管去除对前氧化锆冠骨折的影响

获取原文
获取原文并翻译 | 示例
           

摘要

The objective of this study was to assess the influence of the extension of collar and fatigue cycling on the fracture load of anterior zirconia crowns. A total of 60 anterior full-crown preparations (central incisor) were machined in glass fiberfilled epoxy resin. Zirconia copings were designed and milled using computeraided design/ computer-assisted manufacture (thickness: buccal = 0.62 mm, lingual = 0.65 mm, incisal = 0.72 mm). The cervical collars (occlusogingival height = 0.8 mm, buccolingual width = 1.0 mm) were totally or partially (buccal face) removed for modified copings. They were randomly allocated to six groups according to the type of cervical collar design and the presence (or not) of fatigue cycling (n = 10). The veneering ceramic layer was pressed, and the crowns were cemented with resin cement. The samples were tested until fracture in a universal testing machine and analyzed by stereomicroscopy. Data were statistically analyzed by two-way analysis of variance and Tukey test (5%). Removal of the cervical collar significantly affected the fracture strength of zirconia crowns (P =.000), whereas fatigue cycling did not (P =.428). The mean failure load was lower in the groups with no collar. The most frequent failure modes were cracking of the veneer porcelain in collarless crowns and catastrophic failure in the others. The authors concluded that removal of the vestibular collar of zirconia copings in anterior crowns does not reduce the fracture load of the crowns. However, removal of the entire collar reduces the fracture load and cannot be recommended.
机译:本研究的目的是评估领的延长和疲劳循环对前氧化锆冠断裂载荷的影响。共有60个前全冠预备(中切牙)用玻璃纤维填充环氧树脂加工。使用计算机辅助设计/计算机辅助制造(厚度:颊侧=0.62 mm,舌侧=0.65 mm,切面=0.72 mm)设计和研磨氧化锆覆盖层。全部或部分(颊面)移除颈部项圈(咬合牙龈高度=0.8 mm,颊舌宽度=1.0 mm),以进行改良覆盖。根据颈环设计类型和是否存在疲劳循环(n=10),他们被随机分为六组。对贴面陶瓷层进行加压,并用树脂粘结剂对全冠进行粘接。在万能试验机中对样品进行测试直至断裂,并通过体视显微镜进行分析。数据通过双向方差分析和Tukey检验(5%)进行统计分析。去除颈环显著影响氧化锆冠的断裂强度(P=0.000),而疲劳循环则没有(P=0.428)。无环组的平均失效载荷较低。最常见的失效模式是无领冠的贴面瓷开裂和其他冠的灾难性失效。作者得出结论,去除前牙冠中氧化锆覆盖物的前庭环不会降低牙冠的断裂负荷。然而,移除整个轴环会降低断裂载荷,因此不建议这样做。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号