首页> 外文期刊>Veterinary Radiology & Ultrasound >Use of MRI increases interobserver agreement on gross tumor volume for imaging-diagnosed canine intracranial meningioma
【24h】

Use of MRI increases interobserver agreement on gross tumor volume for imaging-diagnosed canine intracranial meningioma

机译:MRI的使用增加了对成像诊断的犬颅内脑膜瘤的总肿瘤体积的interobserver协议

获取原文
获取原文并翻译 | 示例

摘要

There is a lack of information regarding interobserver agreement on canine meningioma gross tumor volume (GTV) delineation, and on the impact of MRI on this agreement. The objectives of this retrospective, secondary analysis, observer agreement study were to describe agreement between veterinary radiation oncologists on GTV for canine intracranial meningioma, and to compare interobserver agreement between delineation based on CT alone and delineation based on fused CT-MRI. Eighteen radiation oncologists delineated GTV for 13 dogs with an imaging diagnosis of meningioma on pre- and postcontrast CT, pre- and postcontrast T1-weighted magnetic resonance, and T2-weighted magnetic resonance images. Dice similarity coefficient (DSC), concordance index (CI), and center of volume (COV) were used to quantify interobserver agreement. Multilevel mixed models were used to examine the difference in volume, DSC, CI and COV 3D distance between CT and CT-MR imaging. The mean volume for GTV contours delineated using fused CT-MRI was larger than when CT alone was used for delineation (mean difference CT-MR - CT = 0.89 cm(3), 95% CI 0.66 to 1.12,P < .001). Interobserver agreement on GTV was improved when MRI was used; the mean DSC and CI were higher, and the mean COV 3D distance was lower, when fused CT-MRI was used than when CT alone was used (P < .001 for all differences). Based on our results, fused CT-MRI is recommended for radiation therapy planning of canine intracranial meningioma.
机译:关于犬脑膜瘤总肿瘤体积(GTV)描绘的观察者间协议,以及MRI对该协议的影响,缺乏相关信息。这项回顾性、二次分析、观察者一致性研究的目的是描述兽医放射肿瘤学家对犬颅内脑膜瘤GTV的一致性,并比较仅基于CT的描绘与基于融合CT-MRI的描绘之间的观察者一致性。18名放射肿瘤学家为13只狗描绘了GTV,并在对比前后CT、对比前后T1加权磁共振和T2加权磁共振图像上诊断为脑膜瘤。Dice相似系数(DSC)、一致性指数(CI)和体积中心(COV)用于量化观察者之间的一致性。多水平混合模型用于检查CT和CT-MR成像在体积、DSC、CI和COV 3D距离方面的差异。使用融合CT-MRI描绘的GTV轮廓的平均体积大于单独使用CT进行描绘时的体积(CT-MR-CT的平均差值=0.89 cm(3),95%可信区间0.66至1.12,P<0.001)。当使用MRI时,观察者对GTV的一致性得到改善;与单独使用CT相比,使用融合CT-MRI时,平均DSC和CI更高,平均COV 3D距离更低(所有差异均P<0.001)。根据我们的研究结果,融合CT-MRI被推荐用于犬颅内脑膜瘤的放射治疗计划。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号