首页> 外文期刊>Annals of nuclear medicine >Comparison of (99m)Tc-labeled PR81 and its F(ab') fragments as radioimmunoscintigraphy agents for breast cancer imaging.
【24h】

Comparison of (99m)Tc-labeled PR81 and its F(ab') fragments as radioimmunoscintigraphy agents for breast cancer imaging.

机译:比较(99m)Tc标记的PR81及其F(ab')片段作为乳腺癌的放射免疫显像剂。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

OBJECTIVE: We digested anti-MUC1 monoclonal antibody PR81 to produce F(ab') fragments. A comparison was performed between the two radiolabeled PR81 and F(ab') fragments for breast tumor imaging in a mouse model. METHODS: The optimum conditions for pepsin digestion of PR81 were investigated in terms of enzymes: antibody ratio, digestion time duration and preserved immunoreactivity of the produced fragments. The F(ab') fragments were labeled with Technetium-99m using HYNIC as a chelator and tricine as a co-ligand. The immunoreactivity of the complexes was assessed by radioimmunoassay using MCF7 cells. Biodistribution and imaging studies were performed in female BALB/c mice with breast tumor xenograft at 4, 8 and 24 h post-administration. The PR81 was labeled with technetium-99m in the same way for comparison. RESULTS: The optimum time duration for PR81 digestion was found to be 28 h at an enzyme:antibody weight ratio of 1:20 that resulted in 95.2 +/- 4.7% purity. The labeling of intact PR81 and its F(ab') fragments were 87.6 +/- 4.2 and 76.1 +/- 3.3% after 1 h, respectively (p value <0.05). The percentage of immunoreactivity of F(ab') fragments and intact PR81 were 75.4 +/- 2.1% and 85.7 +/- 2.9%, respectively (p value <0.05). The biodistribution and imaging studies demonstrated localization of the fragments at 4 h post-administration with high sensitivity and specificity. CONCLUSION: The results showed that F(ab') fragment of PR81 is more suitable than intact PR81 for safer and more rapid detection of human breast cancer.
机译:目的:我们消化了抗MUC1单克隆抗体PR81以产生F(ab')片段。在两个放射性标记的PR81和F(ab')片段之间进行了比较,以在小鼠模型中进行乳腺肿瘤成像。方法:从酶的角度研究了胃蛋白酶消化PR81的最佳条件:抗体比例,消化持续时间和所产生片段的保留的免疫反应性。使用HYNIC作为螯合剂和Tricine作为共配体,用Technetium-99m标记F(ab')片段。通过使用MCF7细胞的放射免疫测定法评估复合物的免疫反应性。在给药后4、8和24小时,在具有乳腺肿瘤异种移植的雌性BALB / c小鼠中进行了生物分布和成像研究。 PR81也用m 99m进行了标记,以进行比较。结果:在酶与抗体的重量比为1:20的条件下,PR81消化的最佳时间为28小时,其纯度为95.2 +/- 4.7%。 1小时后完整的PR81及其F(ab')片段的标记分别为87.6 +/- 4.2和76.1 +/- 3.3%(p值<0.05)。 F(ab')片段和完整PR81的免疫反应性百分比分别为75.4 +/- 2.1%和85.7 +/- 2.9%(p值<0.05)。生物分布和成像研究表明,在给药后4小时,这些片段的定位具有很高的灵敏度和特异性。结论:PR81的F(ab')片段比完整的PR81更适合于更安全,更快速地检测人乳腺癌。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号