首页> 外文期刊>Annals of nuclear medicine >Comparison of left ventricular functional parameters obtained from three different commercial automated software cardiac quantification program packages and their intraobserver reproducibility.
【24h】

Comparison of left ventricular functional parameters obtained from three different commercial automated software cardiac quantification program packages and their intraobserver reproducibility.

机译:从三个不同的商业自动化软件心脏定量程序软件包获得的左心室功能参数及其观察者内部可重复性的比较。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVE: ECG-gated myocardial perfusion scintigraphy (MPS) can be used to determine several cardiac functional parameters (e.g., left ventricular ejection fraction (LVEF), end-diastolic volume (EDV), and end-systolic volume (ESV)). In this study, we aimed to compare these cardiac functional parameters calculated by the following cardiac quantification programs: Emory Cardiac Toolbox (ECTb), Quantitative Gated SPECT (QGS), and Myometrix. We also evaluated reproducibility of the cardiac programs. METHODS: Fifty-seven patients (27 male, 30 female) at Elazig Research and Training Hospital from 2008 to 2009 were included in this study. In all patients, (99m)Tc-MIBI ECG-Gated (8-bin frame mode) myocardial perfusion scintigraphies were performed. By using 3 different cardiac quantification programs (ECTb, QGS, and Myometrix); LVEF, EDV, and ESV were calculated. The same raw data of MPS images were reprocessed at different time periods, and these 3 parameters were recalculated. LVEF, EDV, and ESV yielded by 3 different programs were compared for interprogram variability assessment, and parameters calculated at two different time periods were compared to evaluate intraprogram reproducibility. RESULTS: There were statistically significant differences between ECTb, QGS, and Myometrix programs for LVEF, EDV, and ESV (p < 0.001). There was also a statistically significant correlation between LVEF and EDV (p < 0.001, r = 0.546; p < 0.001, r = 0.45, respectively), but no statistically significant correlation was present between the ESV values (p > 0.05, r = 0.09). Statistically significant differences were not found between the values of LVEF, EDV, and ESV obtained from the first and second reconstruction analysis of 3 cardiac quantification programs. DISCUSSION: Different MPS cardiac software programs give variable (but correlated) LVEF and left ventricular volumetric measures. Those obtained from different cardiac softwares cannot be used interchangeably. Our findings have shown that ECTb, QGS, and Myometrix programs are reproducible, with respect to LVEF, EDV, and ESV.
机译:目的:心电门控心肌灌注显像(MPS)可用于确定多个心脏功能参数(例如,左心室射血分数(LVEF),舒张末期容积(EDV)和收缩末期容积(ESV))。在这项研究中,我们旨在比较通过以下心脏定量程序计算出的这些心脏功能参数:Emory心脏工具箱(ECTb),定量门控SPECT(QGS)和Myometrix。我们还评估了心脏程序的可重复性。方法:2008年至2009年在Elazig研究与培训医院接受治疗的57例患者(男27例,女30例)被纳入本研究。在所有患者中,均进行了(99m)Tc-MIBI ECG门控(8框模式)心肌灌注显像。通过使用3种不同的心脏定量程序(ECTb,QGS和Myometrix);计算了LVEF,EDV和ESV。在不同时间段对MPS图像的原始数据进行了重新处理,并重新计算了这三个参数。比较了3个不同程序产生的LVEF,EDV和ESV进行程序间可变性评估,并比较了两个不同时间段计算出的参数以评估程序内可重复性。结果:对于LVEF,EDV和ESV,ECTb,QGS和Myometrix程序之间存在统计学差异(p <0.001)。 LVEF和EDV之间也存在统计上的显着相关性(分别为p <0.001,r = 0.546; p <0.001,r = 0.45),但ESV值之间不存在统计学显着的相关性(p> 0.05,r = 0.09) )。从3个心脏定量程序的第一次和第二次重构分析获得的LVEF,EDV和ESV的值之间未发现统计学上的显着差异。讨论:不同的MPS心脏软件程序可提供可变(但相关)的LVEF和左心室容积测量值。从不同的心脏软件获得的软件不能互换使用。我们的发现表明,相对于LVEF,EDV和ESV,ECTb,QGS和Myometrix程序可重现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号