首页> 外文期刊>Analytical methods >Determination of volatile organic compounds in environmental water samples using three solid-phase microextraction fibers based on sol-gel technique with gas chromatography-flame ionization detector
【24h】

Determination of volatile organic compounds in environmental water samples using three solid-phase microextraction fibers based on sol-gel technique with gas chromatography-flame ionization detector

机译:基于固相微萃取-气相色谱-火焰电离检测器的三项固相微萃取纤维测定环境水样中的挥发性有机物

获取原文
获取原文并翻译 | 示例
           

摘要

Sol-gel technology was applied for the preparation of three solid-phase microextraction (SPME) fibers for the extraction of volatile organic compounds (VOCs) from environmental water samples using the gas chromatography-flame ionization detector (GC-FID). The compounds studied were methyl tert-butyl ether (MTBE), tetrahydrofuran (THF), benzene, n-heptane, methyl isobuthyl ketone (MIBK), toluene, tetrachloroethylene, ethylbenzene and o-xylene. These fibers were prepared from different coating polymers including poly(dimethylsiloxane) (PDMS), poly(ethylene glycol) (PEG) and PEG reinforced with multi-walled carbon nanotubes (MWCNTs). Important parameters influencing the extraction efficiency such as extraction temperature, extraction time, stirring speed, salt effect and desorption temperature were investigated and optimized for each fiber. Under the optimal conditions, the dynamic linear range with PDMS, PEG and PEG/CNTs fibers were 0.05-2000, 0.004-2000 and 0.002-2000 ng mL~(-1) and the detection limits (S/N = 3) were 0.02-10, 0.002-1 and 0.001-0.5 ng mL~(-1), respectively. The relative standard deviations (RSD) for one fiber (Repeatability) (n = 3) were obtained from 3.23 up to 7.57% and between fibers or batch to batch (n = 3) (Reproducibility) in the range of 2.91-8.91% for three fibers. However, PEG/CNTs fiber was the best one and the efficiency of PEG/ CNTs was approximately 3 times and twice more than PDMS and PEG at the same conditions for most analytes respectively.
机译:溶胶-凝胶技术用于制备三种固相微萃取(SPME)纤维,用于使用气相色谱-火焰电离检测器(GC-FID)从环境水样品中提取挥发性有机化合物(VOC)。研究的化合物为甲基叔丁基醚(MTBE),四氢呋喃(THF),苯,正庚烷,甲基异丁基基酮(MIBK),甲苯,四氯乙烯,乙苯和邻二甲苯。这些纤维由不同的涂层聚合物制成,包括聚二甲基硅氧烷(PDMS),聚乙二醇(PEG)和用多壁碳纳米管(MWCNT)增强的PEG。研究并优化了影响萃取效率的重要参数,例如萃取温度,萃取时间,搅拌速度,盐效应和解吸温度。在最佳条件下,PDMS,PEG和PEG / CNTs纤维的动态线性范围为0.05-2000、0.004-2000和0.002-2000 ng mL〜(-1),检出限(S / N = 3)为0.02分别为-10、0.002-1和0.001-0.5 ng mL〜(-1)。一根纤维的相对标准偏差(RSD)(重复性)(n = 3)从3.23到7.57%,而纤维或批次之间的相对标准偏差(n = 3)(重现性)在2.91-8.91%范围内。三纤维。然而,PEG / CNTs纤维是最好的一种,在相同条件下,对于大多数分析物而言,PEG / CNTs的效率分别约为PDMS和PEG的3倍和两倍。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号