首页> 外文期刊>Analytical methods >Dynamic solid phase microextraction analysis for airborne methamphetamine: quantitation using isotopicaily substituted methamphetamine
【24h】

Dynamic solid phase microextraction analysis for airborne methamphetamine: quantitation using isotopicaily substituted methamphetamine

机译:空气中甲基苯丙胺的动态固相微萃取分析:使用同位素取代的甲基苯丙胺进行定量

获取原文
获取原文并翻译 | 示例
           

摘要

A vapour dosing system was developed that gave constant concentrations of methamphetamine in the range 1 to 10 ng m~(-3). This was used to calibrate the response of solid phase microextraction (SPME) fibres in passive and dynamic sampling modes. Exposure of 100 urn polydimethylsiloxane SPME fibres to a constant concentration of 1-5 ug m~(-3) methamphetamine over 1-70 min followed by GC-MS analysis produced a curvilinear pre-steady state sorption curve sufficiently reproducible to enable calibration of the SPME absorption. There was no evidence for loss of methamphetamine from the polydimethylsiloxane fibre under static ambient conditions for 5 h or during exposure to 1 L min~(-1) airflow in a dynamic SPME sampler for 90 min at room temperature. Sequential exposure of SPME fibres to methamphetamine and d9-methamphetamine showed that both analytes were retained. These results demonstrate that solid phase microextraction can be used with pre-loaded isotopicaily substituted methamphetamine as an internal standard for accurate quantitation of airborne methamphetamine. The isotopic labeling experiments also showed that the dosing system had a small but significant reservoir of methamphetamine, even though it was constructed from mainly inert materials and much of it was at elevated temperature. We therefore recommend that separate vapour dosing units be used for labeled and unlabeled methamphetamine.
机译:开发了一种蒸气定量给料系统,该系统可提供恒定浓度的甲基苯丙胺,浓度范围为1至10 ng m〜(-3)。这用于校准被动和动态采样模式下固相微萃取(SPME)纤维的响应。在1-70分钟内将100 n的聚二甲基硅氧烷SPME纤维暴露于1-5 ug m〜(-3)甲基苯丙胺的恒定浓度,然后进行GC-MS分析,产生了可重复再现的曲线前稳态吸附曲线,从而能够校准SPME吸收。没有证据表明在静态环境条件下5h或在动态SPME采样器中于室温下暴露于1 L min〜(-1)气流90分钟期间,甲基苯丙胺从聚二甲基硅氧烷纤维中流失。将SPME纤维顺序暴露于甲基苯丙胺和d9-甲基苯丙胺表明,两种分析物均被保留。这些结果表明,固相微萃取可以与预先装载的同位素取代的甲基苯丙胺一起使用,作为内标来精确定量空气中的甲基苯丙胺。同位素标记实验还表明,即使该给药系统主要由惰性材料构成且大部分处于高温下,该给药系统仍具有少量但重要的甲基苯丙胺贮藏库。因此,我们建议将单独的蒸气计量单元用于标记和未标记的甲基苯丙胺。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号