首页> 外文期刊>Analytical methods >Electrochemical characters of hymecromone at the graphene modified electrode and its analytical application
【24h】

Electrochemical characters of hymecromone at the graphene modified electrode and its analytical application

机译:异丁烯酮在石墨烯修饰电极上的电化学特性及其分析应用

获取原文
获取原文并翻译 | 示例
           

摘要

In this paper, a modern popular simple voltammetric sensor, graphene modified electrode (GR/GCE), was employed for studying the electrochemical characters of hymecromone. The electrode reaction of hymecromone was investigated systematically for the first time and some kinetic parameters were calculated. The reaction mechanism of hymecromone at the GR/GCE was also discussed. Based on the enhancement sensing of the GR/GCE for hymecromone, a sensitive electroanalytical method was developed with a detection linear range of 8 x 10(-8) to 6 x 10(-6) mol L-1 and a detection limit of 4 x 10(-8) mol L-1, which were obtained under accumulation for only 180 s. For proving the practical applicability of the proposed method, the determination of hymecromone in real samples was carried out with satisfactory results.
机译:在本文中,现代流行的简单伏安传感器,石墨烯修饰电极(GR / GCE),被用来研究羟甲基丁香酮的电化学特性。首次系统地研究了羟甲香豆素的电极反应,并计算了一些动力学参数。还探讨了羟甲吗啡酮在GR / GCE上的反应机理。基于GR / GCE对羟甲吗啡酮的增强感测,开发了一种灵敏的电分析方法,检测线性范围为8 x 10(-8)至6 x 10(-6)mol L-1,检测极限为4 x 10(-8)mol L-1,仅在累积180 s后获得。为了证明所提方法的实际适用性,对真实样品中的羟甲基吗啡酮进行了测定,结果令人满意。