Further investigation of array capillary in-tube solid-phase microextraction of trace organic pollutants in water samplesf

机译:阵列毛细管内固相微萃取水样中痕量有机污染物的进一步研究f

获取原文
获取原文并翻译 | 示例
           

摘要

Array capillary in-tube solid-phase microextraction (AC1T-SPME) was demonstrated to be a fast, reproducible and convenient extraction method for trace organic pollutants in water samples. In order to improve the extraction efficiency per unit of extraction time, ACIT-SPME cartridges with capillary tubes of different inner diameters (I.D.), from 0.1 mm to 0.5 mm I.D., were fabricated and compared systematically for the extraction of chlorobenzenes (CBs) and nitrochlorobenzenes (NCBs). The results indicated that the ACIT-SPME cartridges with the largest bore diameter were more suitable for rapid extraction of analytes in abundant water samples, while the ACIT-SPME with the smallest bore diameter resulted in the highest absolute recovery. Thus, ACIT-SPME capillary tubes of 0.5 mm I.D. were applied in the rapid extraction of CBs and NCBs from environmental water. Parameters such as sample volume, extraction time, ionic strength, and thermal desorption conditions were investigated to obtain the optimal operation conditions. The extraction was completed in 1.5 min under gravity using 250 mL of water sample. The desorbed analytes were analyzed by gas chromatography (GC) coupled with electron capture detection (ECD). A linear relationship between the peak areas and the concentrations of the analytes covered 2 orders of magnitude with correlation coefficients higher than 0.9961 for all the compounds being studied. The detection limits were between 0.00041 and 0.047 μg L~(-1) with a relative standard deviation (RSD) of between 1.4% and 4.8%. The proposed method was applied in the extraction and determination of CBs and NCBs in real water samples. Relative recoveries and RSDs for the analysis of real water samples were 87.1-116% and 1.8-9.4%, respectively. These results further proved that ACIT-SPME could be applied as a routine sample preparation method for water analysis both in the field and in the lab.
机译:阵列毛细管管内固相微萃取(AC1T-SPME)被证明是一种快速,可重复且方便的水样中痕量有机污染物的提取方法。为了提高每单位提取时间的提取效率,制造了具有不同内径(ID)(内径为0.1 mm至0.5 mm)的毛细管的ACIT-SPME滤芯,并系统地比较了氯苯(CB)和CBs的提取。硝基氯苯(NCB)。结果表明,内径最大的ACIT-SPME柱更适合快速提取大量水样中的分析物,而内径最小的ACIT-SPME的绝对回收率最高。因此,内径为0.5 mm的ACIT-SPME毛细管。应用于从环境水中快速提取CB和NCB。研究了诸如样品量,萃取时间,离子强度和热脱附条件等参数,以获得最佳操作条件。使用250 mL水样品在重力下1.5分钟内完成提取。脱附的分析物通过气相色谱(GC)结合电子捕获检测(ECD)进行分析。峰面积与分析物浓度之间的线性关系覆盖2个数量级,所有正在研究的化合物的相关系数均高于0.9961。检出限在0.00041至0.047μgL〜(-1)之间,相对标准偏差(RSD)在1.4%至4.8%之间。该方法用于实际水样中的CBs和NCBs的提取和测定。实际水样的相对回收率和RSD分别为87.1-116%和1.8-9.4%。这些结果进一步证明,ACIT-SPME可以作为常规样品制备方法用于现场和实验室中的水分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号