首页> 外文期刊>Analytical methods >Comparison between two enzymatic methods for glycated albumin
【24h】

Comparison between two enzymatic methods for glycated albumin

机译:两种酶法测定糖化白蛋白的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Glycated albumin (GA) has attracted considerable interest as an alternative laboratory marker for glycated haemoglobin (A1C). GA reflects a short-term glucose monitoring, and it is not influenced by haemoglobin metabolism. Recently, there have been reports of new enzymatic methodologies for GA measurement. The aim of this study was to perform a comparison between two GA enzymatic assays commercially available in Brazil (Crystal Chem (R) and Diazyme (R)) with samples from adult patients with and without diabetes (N = 85), following CLSI recommendations. For the study, we assessed the diabetic status of patients according to their A1C levels, and we excluded those with clinical conditions that could interfere with GA or A1C levels. We observed a very strong and significant correlation (R = 0.91, p < 0.001) between the methods. The Bland-Altman plot showed a good overall agreement between the GA results (1.2% +/- 2.45%; mean of absolute differences +/- SD), and the Passing-Bablok regression indicated no differences between the assays. The Diazyme (R) GA kit presented a lower analytical imprecision (CV% inter = 8.7%) than Crystal Chem (R) (CV% inter = 10.0%). GA and A1C showed a moderate correlation when measured by the Diazyme (R) or Crystal Chem (R) kits (R = 0.71 and R = 0.63; p < 0.001, respectively). To the best of our knowledge, this is the first study to evaluate the Crystal Chem r kit. Diazyme (R) and Crystal Chem (R) GA assays showed a good correlation with a small difference. The association between GA and A1C demonstrates that this new marker may be a useful alternative when A1C results are unreliable.
机译:糖化白蛋白(GA)作为糖化血红蛋白(A1C)的替代实验室标记物已引起广泛关注。 GA反映了短期血糖监测,不受血红蛋白代谢的影响。近来,已经有关于用于GA测量的新的酶学方法的报道。这项研究的目的是按照CLSI的建议,对巴西有售的两种GA酶法(Crystal Chem(R)和Diazyme(R))与成年糖尿病患者和无糖尿病患者(N = 85)进行比较。在本研究中,我们根据患者的A1C水平评估了患者的糖尿病状况,并排除了可能干扰GA或A1C水平的临床疾病患者。我们观察到这两种方法之间存在非常强烈且显着的相关性(R = 0.91,p <0.001)。 Bland-Altman图显示了GA结果之间的良好总体一致性(1.2%+/- 2.45%;绝对差的平均值+/- SD),并且Passing-Bablok回归表明两种测定法之间没有差异。与Crystal Chem(R)GA(内部CV%= 10.0%)相比,Diazyme(R)GA试剂盒具有更低的分析不精确度(CV%内部= 8.7%)。当用Diazyme(R)或Crystal Chem(R)试剂盒测量时,GA和A1C显示中等程度的相关性(R = 0.71和R = 0.63; p <0.001)。据我们所知,这是第一个评估Crystal Chem r试剂盒的研究。 Diazyme(R)和Crystal Chem(R)GA分析显示出良好的相关性,差异很小。 GA和A1C之间的关联表明,当A1C结果不可靠时,此新标记可能是有用的替代方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号