首页> 外文期刊>Analytical methods >Determination of trace magnesium and strontium in calcium carbonate and calcareous skeletons of marine planktonic organisms using high performance chelation ion chromatography
【24h】

Determination of trace magnesium and strontium in calcium carbonate and calcareous skeletons of marine planktonic organisms using high performance chelation ion chromatography

机译:高效螯合离子色谱法测定海洋浮游生物碳酸钙和钙质骨架中的痕量镁和锶

获取原文
获取原文并翻译 | 示例
           

摘要

A new high performance chelation ion chromatography method for the simultaneous determination of trace magnesium and strontium in various calcium carbonate samples was developed. Separations were performed on a monolithic silica column (Chromolith Si, 100 x 4.6 mm I. D.) chemically modified with hydroxyethyliminodiacetic acid functional groups. At a flow rate of 1.0 mL min(-1), an eluent containing 80 mM NaCl and 20 mM picolinic acid at pH 5.30 was found to provide complete separation of Ni2+, Cu2+, Mg2+, Cd2+, Sr2+ and Ca2+ in 15 minutes, in matrices with 20 000 fold excess of Ca2+. Two post-column reagents, o-cresolphthalein complexone (o-CPC) and ZnEDTA-PAR, were compared for post-column reaction based photometric detection at 570 and 490 nm, respectively. This method provides sensitive detection of Mg2+ (LOD 20 mu g L-1 and 5 mu g L-1 for o-CPC and ZnEDTA-PAR, respectively) and Sr2+ (LOD 200 mu g L-1 and 39 mu g L-1 for o-CPC and ZnEDTA-PAR, respectively). Using o-CPC, the linear range was from 0.5 to 24 mg L-1 for Mg2+ and from 1.0 to 32 mg L-1 for Sr2+. For ZnEDTA-PAR, the linear range was from 0.5 to 4 mg L-1 for Mg2+ and 0.1 to 32 mg L-1 for Sr2+. The method was applied to the analysis of a variety of calcium carbonate samples, including laboratory reagents, limestone NIST certified reference material, and the calcite based shells of marine microorganisms. The accuracy of the method was confirmed using inductively coupled plasma mass spectrometry.
机译:建立了同时测定各种碳酸钙中痕量镁和锶的新型高效螯合离子色谱方法。在用羟乙基亚氨基二乙酸官能团化学修饰的整体式二氧化硅柱(Chromolith Si,100×4.6mm I.D.)上进行分离。在1.0 mL min(-1)的流速下,发现在80°M NaCl和20 mM吡啶甲酸在pH 5.30下的洗脱液可在15分钟内完全分离Ni2 +,Cu2 +,Mg2 +,Cd2 +,Sr2 +和Ca2 +。 Ca2 +过量20 000倍的基质。比较了两种柱后试剂,邻甲酚酞配合物(o-CPC)和ZnEDTA-PAR,分别进行了基于柱后反应的570 nm和490 nm光度检测。该方法可以灵敏地检测Mg2 +(对于o-CPC和ZnEDTA-PAR分别为20μgL-1和5μgL-1的LOD)和Sr2 +(LOD 200μgL-1和39μgL-1的灵敏检测)分别用于o-CPC和ZnEDTA-PAR)。使用o-CPC,线性范围是Mg2 +从0.5到24 mg L-1,Sr2 +从1.0到32 mg L-1。对于ZnEDTA-PAR,线性范围是Mg2 +为0.5至4 mg L-1,Sr2 +为0.1至32 mg L-1。该方法可用于分析各种碳酸钙样品,包括实验室试剂,石灰石NIST认证的参考材料以及基于方解石的海洋微生物壳。使用电感耦合等离子体质谱法确认了该方法的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号