首页> 外文期刊>Analytical methods >Effectiveness of different cleanup sorbents for the determination of avermectins in fish by liquid chromatography tandem mass spectrometry
【24h】

Effectiveness of different cleanup sorbents for the determination of avermectins in fish by liquid chromatography tandem mass spectrometry

机译:液相色谱-串联质谱法测定不同净化吸附剂测定鱼中阿维菌素的有效性

获取原文
获取原文并翻译 | 示例
           

摘要

An effectiveness and comparative study of cleanup sorbents used in dispersive solid phase extraction (DSPE) for the determination of avermectins, including emamectin (EMA), abamectin (ABA), doramectin (DOR), moxidectin (MOX), and ivermectin (IVE), was performed. Three different types of cleanup sorbents, alumina (Al), primary and secondary amine (PSA) and octadecyl (C18), were used to remove the matrix interference in fish samples. Homogenised fish samples were extracted with acetonitrile, magnesium sulphate anhydrous and sodium chloride. The cleanup sorbents were separately applied to the supernatant during the DSPE procedure; the mixtures were shaken and centrifuged, and the supernatant was dried. The extracts were reconstituted with acetonitrile/water and quantified by liquid chromatography tandem mass spectrometry with electrospray ionisation in the positive mode with two product ions that were monitored by selected reaction monitoring. The performance of each cleanup sorbent was observed for its accuracy and precision in a spiked blank sample at a concentration of 5 μg kg~(-1). The combination of the cleanup sorbents PSA and C18 was found to be the most effective in the cleanup of the fish samples. In the validation tests, the detection limit was in the range of 0.3 μg kg~(-1) to 0.4 μg kg~(-1), and the quantitation limit for all avermectins was 1 μg kg~(-1) in the linearity range of 1-15 μg kg~(-1). The recoveries of avermectins were 91.9-102.5%, with a relative standard deviation lower than 19%.
机译:用于分散固相萃取(DSPE)测定阿维菌素的净化吸附剂的有效性和比较研究,这些阿维菌素包括emamectin(EMA),abamectin(ABA),doramectin(DOR),moxidectin(MOX)和伊维菌素(IVE),被执行了。三种不同类型的净化吸附剂,氧化铝(Al),伯胺和仲胺(PSA)和十八烷基(C18)被用于去除鱼样品中的基质干扰物。将均质的鱼样品用乙腈,无水硫酸镁和氯化钠萃取。在DSPE程序中,将清除吸附剂分别应用于上清液;摇动并离心混合物,并将上清液干燥。用乙腈/水重构提取物,并通过液相色谱串联质谱法以正模式电喷雾电离对两种产物离子进行定量,其中两种产物离子通过选定的反应监测器进行监测。观察每种净化吸附剂在加标空白样品中浓度为5μgkg〜(-1)时的准确性和精密度。发现清洁吸附剂PSA和C18的组合在鱼类样品的清洁中是最有效的。在验证试验中,检出限在0.3μgkg〜(-1)至0.4μgkg〜(-1)范围内,所有阿维菌素的定量限线性为1μgkg〜(-1)。范围为1-15μgkg〜(-1)。阿维菌素的回收率为91.9-102.5%,相对标准偏差低于19%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号