A simple, sensitive, and accurate method for the determination of methyl tert-butyl ether (MTBE) in water samples has been developed based on headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-flame ionization detection (GC-FID). A sol-gel based coating fiber using poly(ethylene glycol) (PEG) grafted onto multi-walled carbon nanotubes (PEG-g-MWCNTs) as the extraction phase was prepared and used for the extraction of MTBE. The relative standard deviations (RSDs) for one fiber (repeatability) (n = 6) and between fibers or batch to batch (reproducibility) (n = 3) were obtained. The repeatability was assessed at low (0.1 ng mL~(-1)) and high (100 ng mL~(-1)) concentrations and the RSDs obtained were 5.3 and 4.1%, respectively. The reproducibility obtained for a concentration of 0.1 ng mL~(-1) was 6.5%. The calibration curve of MTBE was linear in the range from 0.07 to 500 ng mL~(-1). The limits of detection (S/N= 3) of 0.01 ng mL~(-1) and the limits of quantification (S/N = 10) of 0.07 ng mL~(-1) were obtained. The developed method was applied successfully to determine trace level of MTBE in real water samples. The relative recoveries for the spiked samples with 5 ng mL~(-1) of MTBE were ranged from 91 to 112% and the relative standard deviations were less than 7.8%.
机译:基于顶空固相微萃取(HS-SPME),然后进行气相色谱-火焰电离检测(GC-FID),开发了一种简单,灵敏,准确的测定水样中甲基叔丁基醚(MTBE)的方法。 )。制备了使用聚(乙二醇)(PEG)接枝到多壁碳纳米管(PEG-g-MWCNTs)作为萃取相的溶胶-凝胶基涂层纤维,并将其用于MTBE的萃取。获得了一根纤维(重复性)(n = 6)和纤维之间或批次之间的相对标准偏差(RSDs)(可重复性)(n = 3)。在低(0.1 ng mL〜(-1))和高(100 ng mL〜(-1))浓度下评估了重复性,得到的RSD分别为5.3%和4.1%。浓度为0.1 ng mL〜(-1)时的重现性为6.5%。 MTBE的校正曲线在0.07至500 ng mL〜(-1)范围内呈线性关系。获得的检出限(S / N = 3)为0.01 ng mL〜(-1),定量限(S / N = 10)为0.07 ng mL〜(-1)。该方法成功应用于实际水样中痕量MTBE的测定。加标浓度为5 ng mL〜(-1)MTBE的样品的相对回收率为91%至112%,相对标准偏差小于7.8%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号