首页> 外文期刊>Analytical methods >Determination of microcystin-LR in surface water by a magnetic bead-based colorimetric immunoassay using antibody-conjugated gold nanoparticles
【24h】

Determination of microcystin-LR in surface water by a magnetic bead-based colorimetric immunoassay using antibody-conjugated gold nanoparticles

机译:基于磁珠的比色免疫分析法,通过抗体偶联金纳米颗粒测定地表水中的微囊藻毒素-LR

获取原文
获取原文并翻译 | 示例
           

摘要

Herein we describe the development of a homogeneous competitive colorimetric immunoassay using antigen-functionalized magnetic beads (MBs) and antibody-immobilized gold nanoparticles (AuNPs) combined with the established gold staining method for the determination of microcystin-leucine-arginine (MC-LR) in surface water. Solid phase extraction proved to be the most beneficial sample preparation method in order to reduce matrix effects which might lead to agglomeration of the AuNPs and failing of the assay. The developed method could detect MC-LR in a linear range from 0.51-11.68 mu g L-1 with a limit of detection (LOD) of 0.38 mu g L-1. The recovery rates of the toxin in spiked water samples were in the range from 88.8% to 117.5%. This proposed immunoassay constitutes a simple and cost-effective method for the detection of sanitary relevant concentrations around 1 mu g L-1 of MC-LR in fresh waters without any expensive or challenging equipment.
机译:在这里,我们描述了使用抗原功能化的磁珠(MBs)和抗体固定的金纳米颗粒(AuNPs)结合已建立的金染色方法测定微囊藻毒素-亮氨酸-精氨酸(MC-LR)的同质竞争比色免疫测定的发展在地表水中。事实证明,固相萃取是最有益的样品制备方法,以减少可能导致AuNP团聚和测定失败的基质效应。所开发的方法可以在0.51-11.68μg L-1的线性范围内检测MC-LR,检测限(LOD)为0.38μg L-1。加标水样中毒素的回收率在88.8%至117.5%之间。该提议的免疫测定方法构成了一种简单且经济高效的方法,无需任何昂贵或具有挑战性的设备即可检测淡水中MC-LR的1μg L-1左右的卫生相关浓度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号