This work describes the coupling of a biomimetic sensor to a flow injection system for the sensitive determination of paracetamol. The sensor was prepared as previously described in the literature (M. D. P. T. Sotomayor, A. Sigoli, M. R. V. Lanza, A. A. Tanaka and L. T. Kubota, J. Braz. Chem. Soc, 2008, 19, 734) by modifying a glassy carbon electrode surface with a Nafion? membrane doped with iron tetrapyridinoporphyrazine (FeTPyPz), a biomimetic catalyst of the P450 enzyme. The performance of the sensor for paracetamol detection was investigated and optimized in a flow injection system (FIA) using a wall jet electrochemical cell. Under optimized conditions a wide linear response range (1.0 x 10~(-5) to 5.0 x 10~(-2) mol L~(-1)) was obtained, with a sensitivity of 2579 (±129) μA L μmol~(-1). The detection and quantification limits of the sensor for paracetamol in the FIA system were 1.0 and 3.5 μmol L~(-1), respectively. The analytical frequency was 51 samples h~(-1), and over a period of five days (320 determinations) the biosensor maintained practically the same response. The system was successfully applied to paracetamol quantification in seven pharmaceutical formulations and in water samples from six rivers in Sao Paulo State, Brazil.
机译:这项工作描述了仿生传感器到流动注射系统的耦合,用于对乙酰氨基酚的灵敏测定。如以前的文献所述(MDPT Sotomayor,A. Sigoli,MRV Lanza,AA Tanaka和LT Kubota,J.Braz.Chem.Soc,2008,19,734)制备传感器,方法是用玻璃电极修饰玻璃碳电极表面。 Nafion?膜中掺杂了四吡啶并卟啉铁(FeTPyPz),一种P450酶的仿生催化剂。在使用壁射流电化学池的流动注射系统(FIA)中,研究并优化了对乙酰氨基酚检测传感器的性能。在最佳条件下,获得了宽线性响应范围(1.0 x 10〜(-5)至5.0 x 10〜(-2)mol L〜(-1)),灵敏度为2579(±129)μALμmol〜 (-1)。 FIA系统中对乙酰氨基酚传感器的检出限和定量限分别为1.0和3.5μmolL〜(-1)。分析频率为51个样本h〜(-1),并且在五天的时间内(320次测定),生物传感器实际上保持了相同的响应。该系统已成功应用于巴西圣保罗州六条河流中的七种药物制剂和水样中的扑热息痛定量分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号