首页> 外文期刊>Analytical methods >Preconcentration and determination of Pb(II), Cu(II) and Cd(II) ions on octadecyl silica membrane disk modified with 2-mercapto-benzoimidazole by flame atomic absorption spectrometry
【24h】

Preconcentration and determination of Pb(II), Cu(II) and Cd(II) ions on octadecyl silica membrane disk modified with 2-mercapto-benzoimidazole by flame atomic absorption spectrometry

机译:火焰原子吸收光谱法对2-巯基苯并咪唑改性的十八烷基二氧化硅膜盘上的Pb(II),Cu(II)和Cd(II)离子进行富集和测定

获取原文
获取原文并翻译 | 示例
           

摘要

In the present work, 2-mercapto-benzoimidazole is used as modifier of octadecyl silica membrane disks (C18 disks) for preconcentration of trace amounts of Pb(II), Cu(II) and Cd(II) ions, followed by nitric acid elution and flame atomic absorption spectrometric (FAAS) determination. The system was offline. The effect of factors influencing the extraction efficiency, i.e., pH of sample solution, amount of ligand, type and volume of eluent, sample solution and eluent flow rates were evaluated and optimized. The optimum pH value was obtained as 6.00. The amount of 3 mg of ligand was obtained as optimum value of sorbent and 5 mL of 2 mol L~(-1) solution of HNO3 with flow rate of 10 mL min~(-1) was obtained as an eluent. Under optimum experimental conditions, the maximum capacity of the membrane disks modified with 3 mg of ligand was found to be 327.8 (±1.6), 245.2 (±1.6) and 211.4 (±1.3) ug for Cu(n), Cd(II) and Pb(II) ions, respectively. The corresponding detection limits were found to be 0.06, 0.14 and 0.18 μg L~(-1) for Cu(II), Cd(II) and Pb(II) ions, respectively. Also the effect of the presence of some probable interfering ions on the recovery of the target metal ions was investigated under the optimized experimental conditions. The proposed method was successfully applied to the determination of Cu(n), Cd(II) and Pb(II) ions in various real samples such as mineral, spring and snow water samples and also it was used for analyzing these metal ions in spinach, nut and wheat samples. The results show that the recoveries are close to 100%, indicating that this method is suitable for determination of these ions in such samples. The reported method in literature was used for the evaluation of the validity of the proposed method and it showed that there were no statistically significant differences between the results obtained by the proposed method with those obtained using the reported method.
机译:在本工作中,将2-巯基苯并咪唑用作十八烷基二氧化硅膜圆盘(C18圆盘)的改性剂,以预富集痕量的Pb(II),Cu(II)和Cd(II)离子,然后进行硝酸洗脱火焰原子吸收光谱法(FAAS)的测定。系统离线。评价和优化影响萃取效率的因素的影响,即样品溶液的pH,配体的量,洗脱液的类型和体积,样品溶液和洗脱液的流速。获得的最佳pH值为6.00。获得3 mg的配体作为吸附剂的最佳值,并获得5 mL HNO3的2 mol L〜(-1)溶液作为洗脱剂,流速为10 mL min〜(-1)。在最佳实验条件下,发现用3 mg配体修饰的膜片的最大容量对Cu(n),Cd(II)为327.8(±1.6),245.2(±1.6)和211.4(±1.3)ug。和Pb(II)离子。发现相应的检测限分别为Cu(II),Cd(II)和Pb(II)离子的0.06、0.14和0.18μgL〜(-1)。在优化的实验条件下,还研究了可能存在的干扰离子对目标金属离子回收率的影响。所提出的方法已成功地用于测定各种真实样品(例如矿物质,春季和雪水样品中)中的Cu(n),Cd(II)和Pb(II)离子,还用于分析菠菜中的这些金属离子,坚果和小麦样品。结果表明回收率接近100%,表明该方法适用于测定此类样品中的这些离子。文献中所报道的方法用于评估所提出方法的有效性,结果表明,所提出方法所获得的结果与所报道方法所获得的结果之间在统计学上没有显着差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号