摘要

A method for determination of arsenic is described. The sensor was constructed by immobilizing reagents on TLC (thin layer chromatography) paper. The reaction is based on chromogenic reaction of arsenic with a coupling complex of sulfanilic acid and N-(1-naphthyl) ethylene diamine dihydrochloride (NEDA) and formation of purple to magenta spots followed by scanner based detection. Changes in RGB values of color spots on TLC strips create a pattern. The obtained pattern was analyzed using MATLAB software. The proposed sensor is linear in the range 1-10 and 25-100 μg mL~(-1). The minimum detection limit found was 0.018μg mL~(-1)of arsenic.
机译:描述了一种测定砷的方法。通过将试剂固定在TLC(薄层色谱)纸上来构造传感器。该反应基于砷与磺胺酸和N-(1-萘基)乙二胺二盐酸盐(NEDA)的偶联络合物的显色反应,并形成紫色至品红色斑点,然后基于扫描仪进行检测。 TLC条带上色点的RGB值变化会产生图案。使用MATLAB软件分析获得的模式。建议的传感器在1-10和25-100μgmL〜(-1)范围内呈线性。最低检出限为0.018μgmL〜(-1)砷。