Bone marrow macroscopic examination remains one of the most difficult and subjective laboratory assessments in hematology. Only a few external quality assurance programs in the field are present worldwide. We have developed an external quality assurance program EQAhem that allows assessment of the whole process of bone marrow examination. The program participants assess blood and bone marrow smears from the patient, identify selected cells from photographs provided to them, and interpret the microscopic results. In this article, the results of the EQAhem program in Poland from 6 years are summarized. During this time, 62 labs were assessed in total, and positive results were achieved by 89.25 % labs, taking into account all tests. Correct responses with respect to the percentage of cell count were provided by ca. 77.5 % labs. Slightly worse results were obtained when megakaryocyte count and cell identification from photographs were tested. The worst results were obtained in case of dysplasia assessment and clinical interpretation of microscopic examination (54.1 and 58.6 % correct responses, respectively). EQAhem delivers precise information about the quality of bone marrow examinations performed in Poland and has a substantial educational value. We believe that after 6 years, EQAhem has significantly improved the quality of bone marrow microscopic examinations performed in Poland.
机译:骨髓宏观检查仍然是血液学领域最困难和最主观的实验室评估之一。全球范围内仅存在少数该领域的外部质量保证计划。我们已经开发了一个外部质量保证计划EQAhem,它可以评估骨髓检查的整个过程。该计划的参与者评估了患者的血液和骨髓涂片,从提供给他们的照片中识别出选定的细胞,并解释了显微结果。本文总结了6年以来波兰EQAhem计划的结果。在此期间,考虑到所有测试,总共评估了62个实验室,并通过89.25%的实验室获得了积极的结果。关于细胞计数的百分比的正确响应由ca提供。 77.5%的实验室。当测试照片中的巨核细胞计数和细胞鉴定时,得到的结果稍差。在发育异常评估和显微镜检查的临床解释的情况下,获得的结果最差(正确答案分别为54.1和58.6%)。 EQAhem可提供有关在波兰进行的骨髓检查质量的精确信息,并具有重要的教育价值。我们相信,六年后,EQAhem大大改善了波兰进行的骨髓显微镜检查的质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号