Modiolar Proximity of Slim Modiolar Electrodes and Cochlear Duct Length: Correlation for Potential Basis of Customized Cochlear Implantation With Perimodiolar Electrodes.

机译:修饰式修炼电极和耳蜗管长度的MODIOLAR接近:与周美岩体电极定制耳蜗植入的潜在基础的相关性。

获取原文
获取原文并翻译 | 示例
           

摘要

Recent studies have shown that cochlear duct length (CDL) varies among individuals and could significantly influence the final position of the electrode and its trajectory in the cochlea. Given this, we hypothesized that the degree of modiolar proximity of novel slim modiolar electrodes, such as CI532 and CI632, can also be affected by CDL. To test this hypothesis, we retrospectively evaluated individual CDL to determine if there is any significant correlation of CDL with degree of modiolar proximity. Fifty-one ears from 38 subjects implanted with slim modiolar electrodes by a single surgeon through the round window approach using the pull-back technique were included. Our cohort was classified according to the deafness onset (congenital versus postlingual) and the degree of modiolar proximity (less versus tight) with reference to the spiral diameter made by the slim modiolar electrodes in situ on transorbital x ray. We then analyzed the CDL and its metrics using a readily available surgical preplanning tool (OTOPLAN) to obtain comparable data. Among 30 ears associated with congenital deafness, 9 ears (30%) showed less modiolar proximity, while none of the 21 ears from 19 subjects with postlingual deafness exhibited "less modiolar proximity" based on our criteria. In this study, CDL showed significant variation among subjects. Importantly, a significant inverse correlation between spiral diameter and CDL (ρ = -0.581, p < 0.001) was found, showing that shorter CDLs have longer spiral diameter and less modiolar proximity. Moreover, further pull-back technique characterized by pulling out the electrode a little bit more in cases with shorter CDL, if not always, exhibited tighter modiolar proximity. A preponderance of less modiolar proximity of the electrode was observed exclusively among congenital deafness cases, demonstrated by a less tight spiral configuration even under the pull-back technique. Our data suggest that shorter CDL is associated with a less tight spiral configuration of slim modiolar electrodes postoperatively. Depending on the insertion technique, the differential degree of modiolar proximity of slim modiolar electrodes can be alleviated in cases with short CDL, which justifies cochlear duct length-based customized insertion of slim modiolar electrodes.
机译:None

著录项

  • 来源
    《Ear and hearing.》 |2021年第2期|共11页
  • 作者单位

    Department of Otorhinolaryngology-Head and Neck Surgery Seoul National University Bundang Hospital;

    Department of Radiology Seoul National University Bundang Hospital;

    Department of Otorhinolaryngology-Head and Neck Surgery;

    Department of Otorhinolaryngology-Head and Neck Surgery Seoul National University Bundang Hospital;

    Department of Otorhinolaryngology-Head and Neck Surgery Seoul National University Bundang Hospital;

    Department of Otorhinolaryngology-Head and Neck Surgery Seoul National University Bundang Hospital;

    Department of Otorhinolaryngology-Head and Neck Surgery Seoul National University Bundang Hospital;

    Department of Otorhinolaryngology-Head and Neck Surgery Seoul National University Bundang Hospital;

    Department of Otorhinolaryngology-Head and Neck Surgery Seoul National University Hospital;

    Department of Otorhinolaryngology-Head and Neck Surgery Seoul National University Hospital;

    Department of Otorhinolaryngology-Head and Neck Surgery Seoul National University Bundang Hospital;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 耳鼻咽喉科学;
  • 关键词

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号