首页> 外文期刊>European Journal of Environmental and Civil Engineering >Bond strength of confined normal strength concrete beam-column joints
【24h】

Bond strength of confined normal strength concrete beam-column joints

机译:狭窄正常强度混凝土梁柱关节粘结强度

获取原文
获取原文并翻译 | 示例
           

摘要

The article presents the results of a research study that was conducted at the American University of Beirut (AUB) on the effect of transverse reinforcement crossing the critical hooked bars region of normal strength concrete (NSC) beam-column joints on the bond strength and ductility of the mode of failure of the hooked bars. Nine full-scale beam-column joint specimens were tested. The specimen simulated the rigid connection of a cantilever vertical beam to a base column. The load was applied near the tip of the beam while the column was fixed to the strong floor. The tensile beam bars were anchored in the column using hooked-bar anchorages. In previous research, confinement to the joint was provided either by carbon fiber reinforced polymer (CFRP) sheets externally confining the joint or steel fibers incorporated in the concrete mix. Results revealed that the transverse reinforcement crossing the hooked bars region was effective in increasing the anchorage capacity and the ductility of the load-deflection history of the specimens. Correlation of the effects of the three different confinement modes is presented.