首页> 外文期刊>Analytical and bioanalytical chemistry >Evaluation of commercial immunoassays for the detection of estrogens in water by comparison with high-performance liquid chromatography tandem mass spectrometry HPLC-MS/MS (QqQ)
【24h】

Evaluation of commercial immunoassays for the detection of estrogens in water by comparison with high-performance liquid chromatography tandem mass spectrometry HPLC-MS/MS (QqQ)

机译:与高效液相色谱串联质谱HPLC-MS / MS(QqQ)进行比较,评估用于检测水中雌激素的商业免疫测定

获取原文
获取原文并翻译 | 示例
           

摘要

In this work four different commercially available enzyme-linked immunosorbent assays (ELISA) (from Japan EnviroChemicals, Ltd., Tokyo, Japan) were evaluated in terms of performance for the rapid screening of estrogens in different water matrices, including natural and spiked samples from urban wastewater, river water and ground water. All four test kits are based on monoclonal antibodies. The compounds detected by these immunoassays are (1) 17-beta-estradiol, (2) estrone, (3) 17-alpha-ethynyl estradiol and (4) estrogens in general, with high recognition properties for 17-beta-estradiol, estrone and estriol. Standards were prepared in water containing 10% (v/v) methanol. The IC (50) (corresponding to the 50% of the effective concentration) values, the dynamic ranges, and the limits of detection of the ELISA kits were 0.060-0.304 mu g/L, 0.05-5 mu g/L and 0.05 mu g/L, respectively. All samples were extracted by solid-phase extraction (SPE) beforehand, and the evaluation was carried out by comparing the results obtained by ELISA with those obtained by HPLC-MS/MS using a triple quadrupole (QqQ) instrument. In addition, two different solid-phase extraction procedures were carried out and compared. Except for moderate overestimation in the results observed with the ELISA kits in the analysis of complex wastewater samples, the results obtained using all of the tested techniques were generally in very good agreement.
机译:在这项工作中,评估了四种不同的可商购的酶联免疫吸附测定(ELISA)(来自Japan EnviroChemicals,Ltd.,东京,日本),用于快速筛选不同水基质中的雌激素,包括天然和加标样品中的雌激素。城市废水,河水和地下水。所有四种测试试剂盒均基于单克隆抗体。通过这些免疫分析检测到的化合物通常是(1)17-β-雌二醇,(2)雌酮,(3)17-α-乙炔基雌二醇和(4)雌激素,它们对17-β-雌二醇,雌酮具有很高的识别特性和雌三醇。在含有10%(v / v)甲醇的水中制备标准液。 ELISA试剂盒的IC(50)(相当于有效浓度的50%)值,动态范围和检测下限为0.060-0.304μg / L,0.05-5μg / L和0.05μg g / L。预先通过固相萃取(SPE)萃取所有样品,并通过使用三重四极杆(QqQ)仪器将ELISA获得的结果与HPLC-MS / MS获得的结果进行比较,从而进行评估。另外,进行了两种不同的固相萃取程序并进行了比较。除了使用ELISA试剂盒分析复杂废水样品中观察到的结果中有高估以外,使用所有测试技术获得的结果通常都非常吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号