首页> 外文期刊>Analytical and bioanalytical chemistry >A flow system with in-line blank correction applied to the spectrophotometric determination of total iron and chromium (VI) in wastewaters
【24h】

A flow system with in-line blank correction applied to the spectrophotometric determination of total iron and chromium (VI) in wastewaters

机译:带有在线空白校正的流量系统用于分光光度法测定废水中的总铁和铬(VI)

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

A flow system using the sample as the carrier with a propulsion device located after the detector is presented. This approach allows the correction of the intrinsic color of the sample, as it provides baseline adjustment for each sample. A confluence situated just after the selection value allows the sample composition to be adjusted for the calorimetric measurement. The developed methodology was applied to the calorimetric determination of total Fe and Cr (VI) in wastewaters at 0.1-6.0 mg L~(-1) and 0.03-1.0 mg L~(-1), respectively. RSD s lower than 35 and a sampling rate of approximately 40 h~(-1) were obtained.
机译:提出了一种使用样品作为载体的流动系统,该流动系统具有位于检测器之后的推进装置。这种方法可以校正样品的固有颜色,因为它可以为每个样品提供基线调整。紧接在选择值之后的汇合点允许调整样品成分以进行比色测量。该方法用于量热法测定废水中总铁和六价铬(VI)的含量分别为0.1-6.0 mg L〜(-1)和0.03-1.0 mg L〜(-1)。 RSD低于35,采样率约为40 h〜(-1)。