...
首页> 外文期刊>Analytical and bioanalytical chemistry >Detection and quantification of benzodiazepines and Z-drugs in human whole blood, plasma, and serum samples as part of a comprehensive multi-analyte LC-MS/MS approach
【24h】

Detection and quantification of benzodiazepines and Z-drugs in human whole blood, plasma, and serum samples as part of a comprehensive multi-analyte LC-MS/MS approach

机译:检测和定量分析人全血,血浆和血清样品中的苯二氮卓类药物和Z-药物,作为全面的多分析物LC-MS / MS方法的一部分

获取原文
获取原文并翻译 | 示例

摘要

For the first time, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) multi-analyte approach based on a simple liquid–liquid extraction was developed and validated for fast target screening and quantification of benzodiazepines and Z-drugs in case of driving ability and crime responsibility in the three most important biosamples whole blood, plasma, and serum. Whole blood, plasma, and serum (500 μL each) were extracted twice at pH 7.4 and at pH 10 with ether/ethyl acetate (1:1). Separation, detection, and quantification were performed using LC-MS/MS with electrospray ionization in positive mode. The method was validated with respect to selectivity, ion suppression/enhancement of co-eluting analytes, matrix effects, recovery, process efficiency, accuracy and precision, stabilities, and limits of detection and quantification. For accuracy and precision, full calibration was performed with ranges from subtherapeutic to toxic concentrations. The presented LC-MS/MS approach as part of a universal multi-analyte concept for over 100 drugs was applicable for selective detection as well as accurate and precise quantification in whole blood, plasma, and serum. The approach was selective, sensitive, accurate, and precise for 16 of the 19 tested drugs in whole blood, 18 in plasma, and 17 in serum. Only semiquantitative results could be obtained for zopiclone because of its instability in all tested biosamples.
机译:首次开发了基于简单液-液萃取的液相色谱-串联质谱(LC-MS / MS)多分析物方法,并经过验证可用于快速目标筛查和定量苯并二氮杂卓和Z药物。三个最重要的生物样本全血,血浆和血清中的驾驶能力和犯罪责任。用乙醚/乙酸乙酯(1:1)在pH 7.4和pH 10下将全血,血浆和血清(各500μL)萃取两次。分离,检测和定量使用LC-MS / MS在正模式下进行电喷雾电离。该方法在选择性,共洗脱分析物的离子抑制/增强,基质效应,回收率,过程效率,准确性和精密度,稳定性以及检测和定量限方面得到了验证。为了准确和精确,在亚治疗浓度至有毒浓度范围内进行了全面校准。提出的LC-MS / MS方法是针对100多种药物的通用多分析物概念的一部分,适用于全血,血浆和血清中的选择性检测以及精确定量。对于全血中的19种测试药物中的16种,血浆中的18种和血清中的17种,该方法具有选择性,灵敏,准确和精确。由于佐匹克隆在所有测试的生物样品中均不稳定,因此只能获得半定量结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号