首页> 外文期刊>Analytical and bioanalytical chemistry >Measurement of water by oven evaporation using a novel oven design. 1. Water in water-saturated 1-octanol, coal, cement, and refined oils
【24h】

Measurement of water by oven evaporation using a novel oven design. 1. Water in water-saturated 1-octanol, coal, cement, and refined oils

机译:使用新颖的烤箱设计,通过烤箱蒸发来测量水。 1.水饱和的1-辛醇,煤,水泥和精制油中的水

获取原文
获取原文并翻译 | 示例
           

摘要

Using an automated oven evaporation technique combined with the coulometric Karl Fischer method, the mass fraction of water has been measured in cement, coal, and refined oil samples. The accuracy of this method was established by using SRM 2890, water-saturated I-octanol that was added to white oil. The samples were analyzed for total reactive Karl Fischer reagent (KFR) material, for interfering materials, and for material that does not react with the aldehyde-ketone KFR. All of the samples yielded volatile material that reacted with the standard KFR. None of the samples contained significant masses of material that reacted with iodine. The cement and coal SRMs contained no material that reacted with methanol and very little material that did not volatilize at 107degreesC. The refined oils contained some material that was volatile at 107degreesC and some at 160degreesC. However, none of this material reacted with the aldehyde-ketone reagent. These results show that the material in the solid samples is water and that the material in the refined oils is a material other than water which reacts with methanol to form water.
机译:使用自动烤箱蒸发技术与电量法卡尔·费休方法相结合,已经测量了水泥,煤炭和精炼油样品中水的质量分数。该方法的准确性是通过使用SRM 2890(加到白油中的水饱和的I-辛醇)确定的。分析样品的总反应性卡尔·费休试剂(KFR)材料,干扰材料和不与醛酮KFR反应的材料。所有样品均产生与标准KFR反应的挥发性物质。样品均未包含与碘反应的大量物质。水泥和煤SRM不含与甲醇反应的物质,极少在107℃下不会挥发的物质。精制油包含一些在107℃下挥发的物质和一些在160℃下挥发的物质。但是,这些物质都没有与醛酮试剂反应。这些结果表明,固体样品中的物质是水,而精制油中的物质是除水以外的与甲醇反应生成水的物质。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号