...
首页> 外文期刊>Analytical and bioanalytical chemistry >Determination of a flame retardant hydrolysis product in human urine by SPE and LC–MS. Comparison of molecularly imprinted solid-phase extraction with a mixed-mode anion exchanger
【24h】

Determination of a flame retardant hydrolysis product in human urine by SPE and LC–MS. Comparison of molecularly imprinted solid-phase extraction with a mixed-mode anion exchanger

机译:通过SPE和LC-MS测定人尿中的阻燃水解产物。用混合模式阴离子交换剂比较分子印迹固相萃取

获取原文
获取原文并翻译 | 示例
           

摘要

Diphenyl phosphate is a hydrolysis product and possible metabolite of the flame retardant and plasticiser additive triphenyl phosphate. A molecularly imprinted polymer solid-phase extraction (MISPE) method for extracting diphenyl phosphate from aqueous solutions has been developed and compared with SPE using a commercially available mixed-mode anion exchanger. The imprinted polymer was prepared using 2-vinylpyridine (2-Vpy) as the functional monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linker, and a structural analogue of the analyte as the template molecule. The imprinted polymer was evaluated for use as a SPE sorbent, in tests with both aqueous standards and spiked urine samples, by comparing recovery and breakthrough data obtained using the imprinted form of the polymer and a non-imprinted form (NIP). Extraction from aqueous solutions resulted in more than 80% recovery. Adsorption by the molecularly imprinted polymer (MIP) was non-selective , but selectivity was achieved by selective desorption in the wash steps. Diphenyl phosphate could also be selectively extracted from urine samples, although the urine matrix reduced the capacity of the MISPE cartridges. Recoveries from urine extraction were higher than 70%. It was important to control pH during sample loading. The MISPE method was found to yield a less complex LC–ESI–MS chromatogram of the urine extracts compared with the mixed-mode anion-exchanger method. An LC–ESI–MS method using a Hypercarb LC column with a graphitised carbon stationary phase was also evaluated for organophosphate diesters. LC–ESI–MS using negative-ion detection in selected ion monitoring (SIM) mode was shown to be linear for diphenyl phosphate in the range 0.08–20 ng μL~(-1).
机译:磷酸二苯酯是阻燃剂和增塑剂添加剂磷酸三苯酯的水解产物和可能的代谢产物。已经开发了一种从水溶液中提取磷酸二苯酯的分子印迹聚合物固相萃取(MISPE)方法,并使用市售的混合模式阴离子交换剂与SPE进行了比较。使用2-乙烯基吡啶(2-Vpy)作为功能单体,使用乙二醇二甲基丙烯酸酯(EGDMA)作为交联剂,使用分析物的结构类似物作为模板分子,制备印迹聚合物。通过比较使用聚合物压印形式和非压印形式(NIP)获得的回收率和穿透数据,评估了压印聚合物用作SPE吸附剂的水样和加标尿液样品。从水溶液中提取可回收80%以上。分子印迹聚合物(MIP)的吸附是非选择性的,但在洗涤步骤中通过选择性脱附实现了选择性。磷酸二苯酯也可以从尿液样本中选择性提取,尽管尿液基质降低了MISPE滤芯的容量。尿液提取的回收率高于70%。在样品加载过程中控制pH值很重要。与混合模式阴离子交换剂方法相比,发现MISPE方法产生的尿液提取物的LC-ESI-MS色谱图不那么复杂。还评估了使用Hypercarb LC色谱柱和石墨化碳固定相的LC-ESI-MS方法的有机磷酸二酯。在选定的离子监测(SIM)模式下使用负离子检测的LC–ESI–MS对于磷酸二苯酯在0.08–20 ngμL〜(-1)范围内呈线性关系。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号