首页> 外文期刊>Analytical and bioanalytical chemistry >Environmental PAH analysis by gas chromatography-atmospheric pressure laser ionization-time-of-flight-mass spectrometry (GC-APLI-MS)
【24h】

Environmental PAH analysis by gas chromatography-atmospheric pressure laser ionization-time-of-flight-mass spectrometry (GC-APLI-MS)

机译:气相色谱-大气压激光电离-飞行时间质谱(GC-APLI-MS)进行环境PAH分析

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The application of polycyclic aromatic hydrocarbon (PAH) analysis by gas chromatography coupled with atmospheric pressure laser ionization and mass spectrometry (GC-APLI-MS) to environmental samples was investigated in the study. The limit of detection for 40 PAH in a standard mixture was 5-100 fg, demonstrating GC-APLI-MS to be a highly sensitive technique and more sensitive by a factor of 100-3,500 compared to GC-MS. Acenaphthylene and cyclopenta[cd]pyrene were not detectable <2,500 fg per injection. To make use of this very high PAH sensitivity, the technique was applied to samples of environmental interest with limited available sample amounts such as particulate matter (PM), soot and a sample from a bioaccumulation test with Lumbriculus variegatus. First, special sample preparation was necessary and ultrasonic extraction proved to be suitable, if a thorough clean-up was performed and plastic materials avoided. By GC-APLI-MS and GC-MS, 224 and 28 single PAH compounds were detected in PM, about 1,000 and 15 in birch soot, and 9 and 2 in worm tissue, respectively, revealing the enormous potential of the method. The selectivity of GC-APLI-MS was shown for a crude oil where >2,200 PAH were detected without any sample preparation.
机译:研究了气相色谱结合大气压激光电离质谱法(GC-APLI-MS)对多环芳烃(PAH)分析在环境样品中的应用。标准混合物中40 PAH的检出限为5-100 fg,表明GC-APLI-MS是一种高度灵敏的技术,与GC-MS相比,灵敏性为100-3,500倍。每次注射都无法检测到<2,500 fg以下的和环戊[cd] re。为了利用这种非常高的PAH敏感性,该技术被用于环境关注的样品,这些样品的可用样品量有限,例如颗粒物(PM),烟灰和来自百日草(Lumbriculus variegatus)的生物蓄积性测试的样品。首先,如果进行了彻底的清理并且避免使用塑料材料,则必须进行特殊的样品制备,并且超声波提取被证明是合适的。通过GC-APLI-MS和GC-MS,分别在PM中检测到224种和28种单一PAH化合物,在桦木烟灰中分别检测到1,000种和15种,在蠕虫组织中检测到9种和2种,揭示了该方法的巨大潜力。显示了GC-APLI-MS对原油的选择性,其中无需任何样品前处理即可检测到> 2,200 PAH。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号