摘要

Capillary zone electrophoresis was employed to the analysis of glutathione by using end-column amperometric detection with a gold/mercury amalgam microelectrode at a constant potential of 0.02 similar to 0.06 V vs. SCE. In this procedure deoxygenation is not necessary. The calibration plot was found to be linear over 4 orders of magnitude and the limit of detection was 6.3x10(-7) mol l(-1) (or 126 amol). The effect of the concentration of the buffer, and the high separation voltage across the capillary on the migration time and separation efficiency, and the dependence of the injection conditions on the detection signal, the separation efficiency and the coulometric efficiency have been investigated. The method was applied to the determination of glutathione in human blood and erythrocytes.
机译:毛细管区带电泳用于谷胱甘肽的分析,方法是使用金/汞齐汞合金微电极,以0.02的恒定电位(相对于SCE而言为0.06 V)进行柱端安培检测。在此过程中,脱氧是没有必要的。发现校准曲线在4个数量级上呈线性,检测极限为6.3x10(-7)mol l(-1)(或126 amol)。研究了缓冲液浓度,毛细管上高分离电压对迁移时间和分离效率的影响,以及进样条件对检测信号,分离效率和库仑效率的依赖性。该方法用于人血和红细胞中谷胱甘肽的测定。