...
首页> 外文期刊>Analytica chimica acta >A rapid and reliable method for Pb isotopic analysis of peat and lichens by laser ablation-quadrupole-inductively coupled plasma-mass spectrometry for biomonitoring and sample screening
【24h】

A rapid and reliable method for Pb isotopic analysis of peat and lichens by laser ablation-quadrupole-inductively coupled plasma-mass spectrometry for biomonitoring and sample screening

机译:激光烧蚀-四极杆-电感耦合等离子体质谱法快速可靠地分析泥炭和地衣中的铅同位素,用于生物监测和样品筛选

获取原文
获取原文并翻译 | 示例
           

摘要

An analytical protocol for rapid and reliable laser ablation-quadrupole (LA-Q)- and multi-collector (MC-) inductively coupled plasma-mass spectrometry (ICP-MS) analysis of Pb isotope ratios (~(207)Pb/~(206)Pb and ~(208)Pb/~(206)Pb) in peats and lichens is developed.This technique is applicable to source tracing atmospheric Pb deposition in biomonitoring studies and sample screening.Reference materials and environmental samples were dry ashed and pressed into pellets for introduction by laser ablation.No binder was used to reduce contamination.LA-MC-ICP-MS internal and external precisions were <1.1% and <0.3%,respectively,on both ~(207)Pb/~(206)Pb and ~(208)Pb/~(206)Pb ratios.LA-Q-ICP-MS internal precisions on ~(207)Pb/~(206)Pb and ~(208)Pb/~(206)Pb ratios were lower with values for the different sample sets <14.3% while external precisions were <2.9%.The level of external precision acquired in this study is high enough to distinguish between most modern Pb sources.LA-MC-ICP-MS measurements differed from thermal ionisation mass spectrometry (TIMS) values by 1% or less while the accuracy obtained using LA-Q-ICP-MS compared to solution MC-ICP-MS was 3.1% or better using a run bracketing (RB) mass bias correction method.Sample heterogeneity and detector switching when measuring ~(208)Pb by Q-ICP-MS are identified as sources of reduced analytical performance.
机译:快速可靠的激光烧蚀四极杆(LA-Q)和多收集器(MC-)电感耦合等离子体质谱(ICP-MS)分析铅同位素比(〜(207)Pb /〜(开发了泥炭和地衣中的206)Pb和〜(208)Pb /〜(206)Pb),该技术适用于在生物监测研究和样品筛选中追踪大气中Pb的来源,将参考材料和环境样品干灰并压制〜(207)Pb /〜(206)上LA-MC-ICP-MS的内部和外部精度分别<1.1%和<0.3% Pb和〜(208)Pb /〜(206)Pb比。〜(207)Pb /〜(206)Pb和〜(208)Pb /〜(206)Pb比的LA-Q-ICP-MS内部精度分别为较低,不同样品组的值<14.3%,而外部精密度<2.9%。本研究中获得的外部精密度水平足以区分大多数现代铅源.LA-MC-ICP-MS测量与热电离质谱(TIMS)值相差1%或更小,而使用运行包围(RB)质量偏差,与溶液MC-ICP-MS相比,使用LA-Q-ICP-MS获得的准确度为3.1%或更高通过Q-ICP-MS测定〜(208)Pb时,样品异质性和检测器切换被认为是降低分析性能的来源。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号