...
首页> 外文期刊>Analytica chimica acta >New generation of cyanide ion-selective membranes for flow injection application - Part II. Comparative study of cyanide flow-injection detectors based on thin electroplated silver chalcogenide membranes
【24h】

New generation of cyanide ion-selective membranes for flow injection application - Part II. Comparative study of cyanide flow-injection detectors based on thin electroplated silver chalcogenide membranes

机译:用于流动注射的新一代氰化物离子选择性膜-第二部分。基于电镀硫属元素银薄膜的氰化物流动注入检测器的比较研究

获取原文
获取原文并翻译 | 示例
           

摘要

Using induced cathodic electrodeposition a number of silver chalcogenide thin layer membranes of non-trivial composition have been synthesized and their performance as ion-selective flow-injection potentiometric detectors (FIPDs) for free cyanide has been critically estimated in the context of the stringent requirements for toxic cyanide environmental monitoring. AgSCN/Ag2S, Ag2S, Ag2+delta Se, Ag2+delta Se1-xTex (0 < delta < 0.25 and x approximate to 0.13), Ag2Se and Ag2Se1-xTex electroplated membranes were selected for the present performance-based comparative study in order to obtain a feedback information about the effect of membrane composition. Both silver selenide and Te-doped silver selenide membranes, irrespective of their stoichiometry with respect to silver, exhibit the lowest detection limit for CN- (52 ppb) with linear double-Nernstian response down to 130 ppb. The type of chalcogene anion in the membrane composition proves to exert dominant effect on the general performance characteristics of the newly developed FIPDs. The silver stoichiometry (intrinsic defects factor) and the inclusion of Te-dopant (extrinsic defects factor) have more pronounced effect on the profile of the output signal and exert moderate control on the detectors selectivity and baseline stability. This new generation of CN--ion-selective membranes for FIPDs exhibits high selectivity against the common interferents present in cyanide effluents such as SCN-, S2O32-, Cl- and do not get poisoned in the presence of S2-. Moreover, their long-term stability and signal reproducibility, which make redundant the regular day-to-day calibration, coupled with the cost-effective technology for membranes preparation and easy re-generation make them attractive candidates for incorporation into automated in-field devices for in situ cyanide toxic species monitoring. (c) 2006 Elsevier B.V. All rights reserved.
机译:使用诱导阴极电沉积,已经合成了许多非平凡的硫属元素化银薄层膜,并且在对有机氰化物的严格要求的背景下,已对它们作为游离氰化物的离子选择性流动注射电位检测器(FIPD)的性能进行了严格评估。有毒氰化物环境监测。选择AgSCN / Ag2S,Ag2S,Ag2 + delta Se,Ag2 + deltaSe1-xTex(0

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号