首页> 外文期刊>Analytica chimica acta >Evaluation of certified reference materials for oxidation-reduction titration by precise coulometric titration and volumetric analysis
【24h】

Evaluation of certified reference materials for oxidation-reduction titration by precise coulometric titration and volumetric analysis

机译:通过精确的库仑滴定和体积分析评估认证的参考材料用于氧化还原滴定

获取原文
获取原文并翻译 | 示例
           

摘要

The accuracy and uncertainty of coulometric titration of Japanese certified reference materials (CRMs) for oxidation-reduction titration were examined in this study.The results for potassium dichromate,sodium oxalate,and potassium iodate are presented.Potassium dichromate was directly determined by coulometric titration,and sodium oxalate and potassium iodate were determined by volumetric analysis using potassium dichromate assigned by coulometry.The uncertainty of the method was investigated by examining the dependency on the sample size and on the electrolysis current.Changes in the titration parameters did not result in any significant effects on the titration results.The coulometric system used primarily consists of a constant current source,timer,switching circuit,indicator unit,and voltmeter.They were controlled using the coulometry software by a PC/AT compatible computer.A highly automated coulometric system achieves repeatabilities of less than one part in 30,000 (k = 2) and uncertainties of less than one part in 15,000 (k = 2).In addition,using volumetric method,SI units traceable sodium oxalate and potassium iodate (purity standards for redox reaction) CRMs were developed.Reference materials for volumetric analysis are the most basic substances used in analytical chemistry.These materials are analyzed by several analytical methods and are produced globally;however,their purities have not been compared at the international level.Therefore,the relationship between the purity and reliability of these materials has not yet been established.In this paper,we determine the relationship between these parameters by titrating each material obtained from different laboratories.
机译:本研究检验了日本认证参考物质(CRM)用于氧化还原滴定的库仑滴定的准确性和不确定性,给出了重铬酸钾,草酸钠和碘酸钾的测定结果,通过库仑滴定直接测定重铬酸钾,用电量法分配的重铬酸钾通过体积分析法测定草酸钠和碘酸钾,并通过检查对样品大小和电解电流的依赖性来研究该方法的不确定性。滴定参数的变化不会导致任何显着影响影响的滴定结果。所使用的电量分析系统主要由恒流源,计时器,开关电路,指示器单元和电压表组成。它们通过电量分析软件由PC / AT兼容计算机进行控制。重复性小于30,000(k = 2)的1分之一确定性不到15,000(k = 2)的一分之一。此外,使用体积法,开发了可溯源的SI单位草酸钠和碘酸钾(氧化还原反应的纯度标准)CRM。用于体积分析的参考材料是最基本的物质这些材料通过多种分析方法进行了分析并在全球范围内生产;然而,它们的纯度尚未在国际上进行比较,因此,这些材料的纯度与可靠性之间的关系尚未建立。本文通过滴定从不同实验室获得的每种材料来确定这些参数之间的关系。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号