Resonance Rayleigh scattering (RRS) of cadmium(II)-iodide-rhodamine dye systems and their analytical application have been studied. In dilute phosphoric acid, rhodamine dyes such as rhodamine B (BRhB), ethylrhodamine B (ERhB), butylrhodamine B (BRhB) and rhodamine 6G (Rh6G) have characteristic RRS spectra and their maximum RRS wavelengths (lambda(max)) are at 575 nm for RhB, ERhB and BRhB, and 545 nm for Rh6G. In the presence of a large excess of I-, cadmium(II) forms [CdI4](2-), which further reacts with a rhodamine dye to form an ion-association compound. This results in significant enhancement of RRS intensity and the appearance of new spectra with lambda(max) at 610 nm for RhB, ERhB and BRhB systems and 585nm for the Rh6G system. The characteristics of the RRS spectra of the ion-association compounds, the affecting factors and the optimum conditions of these reactions have been investigated. The intensity of RRS is directly proportional to the concentration of cadmium in the range 0-1.0 mu g/25 mi for all the systems. The methods have high sensitivities and the detection limits for cadmium are 0.60-1.26 ng ml(-1) depending on the reaction system; the Rh6G system is the most sensitive. A new method for the determination of trace cadmium on the basis of RRS is described. (C) 2000 Elsevier Science B.V. All rights reserved. [References: 25]
机译:研究了镉(II)-碘化物-罗丹明染料体系的共振瑞利散射(RRS)及其分析应用。在稀磷酸中,若丹明B(BRhB),乙基若丹明B(ERhB),丁基若丹明B(BRhB)和若丹明6G(Rh6G)等罗丹明染料具有特征性RRS光谱,并且它们的最大RRS波长(lambda(max))为575。 RhB,ERhB和BRhB的最大波长为150 nm,Rh6G为545纳米。在大量过量的I-存在下,镉(II)形成[CdI4](2-),它进一步与若丹明染料反应形成离子缔合化合物。对于RhB,ERhB和BRhB系统,λ最大值为610 nm,对于Rh6G系统为585nm,λ最大值在λnm时,RRS强度和新光谱的出现显着增强。研究了离子缔合化合物的RRS光谱特征,影响因素和最佳反应条件。对于所有系统,RRS的强度与镉的浓度成正比,范围为0-1.0μg/ 25 mi。该方法灵敏度高,根据反应体系的不同,镉的检出限为0.60-1.26 ng ml(-1)。 Rh6G系统是最敏感的。介绍了一种基于RRS测定痕量镉的新方法。 (C)2000 Elsevier Science B.V.保留所有权利。 [参考:25]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号