A method is described for the determination of ultra-trace elements (Li, Be, Na, Mg, Al, K, Ca, Ti, V, Cr, Mn, Fe. Co. Ni, Cu, Zn, Ga, Ge, Sr, Mo, Ag, Cd, Sn, Sb, Ba, Ti, Pb and Bi) in electronic-grade water and chemicals by inductively coupled plasma mass spectrometry (ICP-MS). In order to achieve the highly sensitive determination and to prevent spectral interference from matrix of chemicals, the sample was concentrated by a non-boiling evaporation technique. The presence of polyhydric alcohols having two or more hydroxyl groups in cis position, especially dulcitol, was effective in preventing vaporization loss of analytes such as Ti, Ge, Sn and Sb. The presence of dulcitol did not influence ICP-MS intensities for a]) the elements. This method was applied to the determination of ultra-trace impurities in electronic-grade water and ammonia water.
机译:描述了一种测定超痕量元素(Li,Be,Na,Mg,Al,K,Ca,Ti,V,Cr,Mn,Fe。Co. Ni,Cu,Zn,Ga,Ge,Sr电感耦合等离子体质谱法(ICP-MS)测定电子级水和化学药品中的二价钼,钼,银,镉,锡,锑,钡,钛,铅和铋)。为了实现高度灵敏的测定并防止化学基质的光谱干扰,通过非沸腾蒸发技术对样品进行浓缩。在顺式位置具有两个或多个羟基的多元醇,特别是二甘醇的存在可有效地防止被分析物诸如Ti,Ge,Sn和Sb的蒸发损失。二醇的存在不影响a))元素的ICP-MS强度。该方法用于电子级水和氨水中超痕量杂质的测定。