The feasibility of a solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) for "the particle analysis of safeguards environmental swipe samples" was studied with polycarbonate (PC) film samples containing thallium (Tl),lead (Pb) and uranium (U) particles in single element and with their solution sample.The influences of instrumental operating conditions on analytical results,especially accuracy and precision in isotope ratio measurements,were investigated.Isotope ratios obtained for Tl and Pb solution samples containing a few picogram amounts of particles were in good agreement with the reference values obtained using pneumatic nebulizer ICP-MS.It is revealed that when vaporization temperature was set to be optimal,the pyrolysis temperatures in the temperature range of this study did not affect the magnitude of integrated signals.Isotope ratios obtained for PC film samples including a few picogram amounts of particles were comparable to those of solution samples,and good values of isotope ratio were obtained in the wide range of measurement parameters even though analyte losses occurred in inappropriate temperature conditions.The pyrolysis and vaporization temperature dependence of the integrated signal was different from those of the solution sample,which is ascribed to the difference of transport efficiency of the vaporized analyte in both samples.Absolute limit of detection for PC film sample was found to be about 2 fg,which corresponds to 2 pg/g for a typical sample mass of 1 mg.
机译:用含sampling(Tl),铅(Pb)的聚碳酸酯(PC)薄膜样品研究了固体采样电热汽化电感耦合等离子体质谱法(ETV-ICP-MS)用于“保障措施环境擦拭样品的颗粒分析”的可行性。和铀元素(U)颗粒及其溶液样品。研究了仪器操作条件对分析结果的影响,尤其是同位素比测量的准确度和精密度。颗粒数量与使用气动雾化器ICP-MS获得的参考值非常吻合。研究表明,当将蒸发温度设置为最佳时,本研究温度范围内的热解温度不会影响积分信号的大小。包含少量皮克数量颗粒的PC膜样品的同位素比与即使在不适当的温度条件下发生分析物损失,也能在宽范围的测量参数中获得溶液样品的剂量和良好的同位素比值。积分信号的热解和汽化温度依赖性与溶液样品的不同。 PC薄膜样品的绝对检测极限约为2 fg,相当于1 mg典型样品质量的2 pg / g。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号