Trace impurities in gallium samples were determined by inductively coupled plasma mass spectrometry (ICP-MS) after enrichment of trace impurities, nobler than Ga (Ag, Bi, Co, Cu, Fe, Ni, and Pb) on residual gallium in a mixture of HCl and HNO3 (Jackwerths' procedure). The elements leached into the solution (Al, Cd, and Mn) were determined by removing the matrix from the solution after HCl-MIBK extraction. Direct determination after dissolution of gallium in nitric acid was also attempted. Interferences encountered in the determination are discussed. The results obtained have been cross validated with transverse heated graphite furnace atomic absorption spectrometry (THGFAAS) and the correlation coefficient R was found to be 0.995. Limit of detection in mg/kg obtained by ICP-MS were 0.0003 for Ag; 0.008 for Bi; 0.008 for Cu; 0.007 for Ni; 0.003 for Pb and by THGFAAS were 0.0014 for Ag; 0.075 for Bi; 0.005 for Cu; 0.003 for Ni and 0.004 far Pb after partial dissolution taking 2.0 g of the sample. For Co the limit of detection by both the techniques was 0.003 mg/kg while 0.003 mg/kg was obtained for Fe using THGFAAS. (C) 1998 Elsevier Science B.V. All rights reserved. [References: 17]
机译:痕量杂质的富集比残留的镓中Ga(Ag,Bi,Co,Cu,Fe,Ni和Pb)高(Ga)的痕量杂质富集后,通过电感耦合等离子体质谱(ICP-MS)测定镓样品中的痕量杂质。 HCl和HNO3(Jackwerths程序)。在HCl-MIBK萃取后,通过从溶液中除去基质来确定浸出到溶液中的元素(Al,Cd和Mn)。还尝试了镓在硝酸中溶解后的直接测定。讨论了确定过程中遇到的干扰。所得结果已通过横向加热石墨炉原子吸收光谱法(THGFAAS)进行了交叉验证,相关系数R为0.995。 ICP-MS测定的Ag的检出限(mg / kg)为0.0003; Bi为0.008;铜0.008;镍0.007; Pb和THGFAAS的0.003对Ag为0.0014;铋0.075;铜0.005;镍为0.003,部分溶解后为0.004远Pb,取2.0 g样品。对于Co,两种技术的检出限为0.003 mg / kg,而使用THGFAAS获得的Fe为0.003 mg / kg。 (C)1998 Elsevier Science B.V.保留所有权利。 [参考:17]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号