首页> 外文期刊>Analytica chimica acta >Simultaneous determination of fluorophores with overlapped spectra by sequential injection analysis coupled to variable angle scanning fluorescence spectrometry and multivariate linear regression algorithms
【24h】

Simultaneous determination of fluorophores with overlapped spectra by sequential injection analysis coupled to variable angle scanning fluorescence spectrometry and multivariate linear regression algorithms

机译:顺序注入分析结合可变角扫描荧光光谱法和多元线性回归算法同时测定重叠光谱的荧光团

获取原文
获取原文并翻译 | 示例
           

摘要

An automated and versatile sequential injection spectrofluorimetric procedure for the simultaneous determination of multicomponent mixtures in micellar medium without prior separation processes is reported. The methodology is based upon the segmentation of a sample slug between two different buffer zones in order to attain both an imporvement of sensitivity and residual minimization for the whole species. Resolution of overlapping lfuorescence profiles is achieved using a variable angle scanning technique coupled to multivariate least-squares regression (MLR) algorithms at both sample edges. The potnetialities of the described methodology are illustrated with the spectrofluorimetric determination of four widespread pesticides with different acid-base properties; viz. carbaryl (CBL) (1-napthyl-N-methylcarbamate), fuberidazole (FBZ)(2-(2'-furyl)benzimidazole), thiabendazole (TBZ) (2-(4'-thiazolyl) benzimidazole) and warfarin (W) (3-alpha-acetonylbenzyl)-4-hydroxycoumarin). Detection limits at the 3sigma level were 3.9, 0.02, 0.03 and 10 mu g l~(-1) for CBL, FBZ, TBZ and W, respectively at the maximum sensitivity pH. Dynamic ranges of 13-720 mu g l~(-1) CBL, 0.10-14 mug l~(-1) FBZ, 0.19-60 mu g l~(-1) TBZ and 0.05-5 mg l~(-1) W were achieved. Relative standard deviations (n=10) were 0.2% for 100 mu g l~(-1) CBL and 2.4 mu g l~(-1) FBZ, 0.7% for 8 mug l~(-1) TBZ and 1.0% for 1 mg l~(-1) W. The proposed automated methodology, which handles 17 samples/h, was validated and applied to spiked real water samples with very satisfactory results.
机译:据报道,无需事先进行分离过程,即可同时测定胶束介质中的多组分混合物的自动,通用的顺序注射荧光光谱法。该方法基于两个不同缓冲区之间的样本段的分割,从而既提高了灵敏度,又使整个物种的残留量最小化。使用可变角度扫描技术和两个样本边缘的多元最小二乘回归(MLR)算法,可以实现重叠荧光轮廓的解析。通过荧光荧光法测定四种具有不同酸碱性质的农药,说明了所描述方法的效价。即西维因(CBL)(1-萘基-N-甲基氨基甲酸酯),氟哌达唑(FBZ)(2-(2'-呋喃基)苯并咪唑),噻苯达唑(TBZ)(2-(4'-噻唑基)苯并咪唑)和华法林(W) (3-α-丙酮基苄基)-4-羟基香豆素)。在最高灵敏度pH值下,CBL,FBZ,TBZ和W在3sigma浓度下的检出限分别为3.9、0.02、0.03和10μg l〜(-1)。动态范围13-720 mu gl〜(-1)CBL,0.10-14杯l〜(-1)FBZ,0.19-60 mu gl〜(-1)TBZ和0.05-5 mg l〜(-1)W实现了。相对标准偏差(n = 10)对于100 mu gl〜(-1)CBL和2.4 mu gl〜(-1)FBZ为0.2%,对于8杯l〜(-1)TBZ为0.7%,对于1 mg为1.0 mg l〜(-1)W.所提出的自动方法(每小时处理17个样品)经过验证,并应用于加标的真实水样中,结果非常令人满意。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号