首页> 外文期刊>Analytica chimica acta >Spectrophotometric resolution of ternary mixtures of pseudoephedrine hydrochloride,dextromethorphan hydrobromide,and sodium benzoate in syrups using wavelength selection by net analyte signals calculated with hybrid linear analysis
【24h】

Spectrophotometric resolution of ternary mixtures of pseudoephedrine hydrochloride,dextromethorphan hydrobromide,and sodium benzoate in syrups using wavelength selection by net analyte signals calculated with hybrid linear analysis

机译:通过使用混合线性分析计算的净分析物信号进行波长选择,分光光度法测定糖浆中伪麻黄碱,氢溴酸右美沙芬和苯甲酸钠的三元混合物

获取原文
获取原文并翻译 | 示例
       

摘要

Hybrid linear analysis(HLA),as a recent factor-based multivariate calibration technique,was applied for the Spectrophotometric determination of ternary mixtures of pseudoephedrine hydrochloride(PSU),dextromethorphan hydrobromide(DXT),and sodium benzoate(BNZ).The utilized HLA was assisted by a wavelength selection procedure which was based on the calculation of the net analyte signal(NAS)regression plot in any considered wavelengths window for each test sample,in addition to a moving window strategy for searching the region with maximum linearity of NAS regression plot(minimum error indicator(EI)).HLA was applied because it was simpler to adapt to the NAS regression plot methodology,and also used less factors than partial least squares(PLS).An orthogonal array design was applied for formation of calibration and prediction sets in the concentration ranges 0-7500 mumol L~(-1)for PSU,0-300 mumol L~(-1)for DXT,and 0-1400 mumol L~(-1)for BNZ.The method had the ability to select wavelength regions that minimize the effect of non-linearity of the spectral data,in addition to that of non-modeled interferences.The application of the selected wavelength regions improved the obtained relative standard error of predictions for PSU,DXT,and BNZ,respectively,from 5.24,8.67,and 5.48% to 2.19,5.21,and 3.62%(using lower number of factors).To check the ability of the proposed method in selection of linear regions of spectra,a test for detecting non-linear regions of spectral data in multivariate spectroscopic assays was also described.Additives in the commercial syrup samples did not interfere with their determinations.The method was successfully applied for the determination of pseudoephedrine HC1,dextromethorphan HBr,and sodium benzoate in cough suppressant syrup samples.
机译:混合线性分析(HLA)作为一种基于因子的最新多元校正技术,用于分光光度法测定盐酸伪麻黄碱(PSU),氢溴酸右美沙芬(DXT)和苯甲酸钠(BNZ)的三元混合物。借助波长选择程序,该程序基于对每个测试样品在任何考虑的波长范围内的净分析物信号(NAS)回归图的计算,以及用于搜索具有最大线性度的NAS回归图的区域的移动窗口策略(最小误差指示符(EI)。)之所以使用HLA,是因为它更容易适应NAS回归图方法,并且比偏最小二乘(PLS)使用的因子更少。正交阵列设计用于校准和预测的形成设定PSU的浓度范围为0-7500 mumol L〜(-1),DXT的浓度范围为0-300 mumol L〜(-1),BNZ的浓度范围为0-1400 mumol L〜(-1)。选择波长除非建模干扰外,还可以最大程度地减少光谱数据非线性影响的区域。选定波长区域的应用分别从以下方面改善了PSU,DXT和BNZ预测的相对标准误差5.24、8.67和5.48%至2.19、5.21和3.62%(使用较少的因子)。要检查该方法在选择光谱线性区域中的能力,请执行一项检测光谱数据非线性区域的测试市售糖浆样品中的添加剂也不会影响其测定。该方法已成功地用于测定止咳糖浆中的伪麻黄碱HC1,右美沙芬HBr和苯甲酸钠。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号