Sequential injection spectrophotometric determination of orthophosphate in beverages,wastewaters and urine samples by electrogeneration of molybdenum blue using tubular flow-through electrodes

机译:管状流通电极通过钼蓝的电动进样分光光度法测定饮料,废水和尿液中的正磷酸盐

获取原文
获取原文并翻译 | 示例
       

摘要

A novel and automated sequential injection procedure is proposed for the spectrophotometric determination of orthophosphate without requiring unstable chemical reducing species used in the classical molybdenum blue method.The flowing methodology is based on the on-line generation of the detectable species by electrochemical reduction of the 12-molybdophosphoric acid complex using a stainless steel tubular flow-through working electrode.The established method is linear up to 20 mg/l P,with coefficients of variation (n=10) of 2.4 and 1.8% for 2.0 and 10 mg/l P,respectively.The versatility of the sequential injection method to analyse samples containing high orthophosphate levels has been demonstrated by the implementation of a dilution chamber as well as flow-reversal techniques,yielding relative standard deviations (n=17) better than 2.0% for standards containing 200 and 800 mg/1 P.The proposed analyser features an extremely wide dynamic range (viz.,0.3-800 mg/1) as well as improved tolerance to silicate interference,so that Si/P ratios higher than 50 are tolerated at the 5% level.Electrochemical conditions,reagent concentrations and physical variables have been thoroughly investigated.The method has been applied to the determination of orthophosphate in wastewaters as well as beverages and biological samples containing high concentrations of the target analyte.The t-test comparison of the means for the developed sequential injection system with electroreduction and both the molybdenum blue classical spectrophotometric batch procedure and inductively coupled plasma-optical emission spectrometric detection selected as external reference methods revealed that there is no evidence of significant differences between the obtained results at the 95% confidence level.
机译:提出了一种新颖的自动顺序进样程序,用于分光光度法测定正磷酸盐,而无需使用经典的钼蓝方法中使用的不稳定化学还原物种。流动方法基于通过电化学还原12种可检测物种的在线生成-磷钼酸配合物,使用不锈钢管状流通电极。已建立的方法线性高达20 mg / l P,2.0和10 mg / l P的变异系数(n = 10)为2.4和1.8%分别采用稀释室和逆流技术证明了顺序进样方法分析高正磷酸盐水平样品的多功能性,相对标准偏差(n = 17)优于标准品的2.0%包含200和800 mg / 1 P.拟议的分析仪具有极宽的动态范围(即0.3-800 mg / 1)以及改进的Tol提高了硅酸盐的抗干扰性,使Si / P比在50%时可耐受5%。彻底研究了电化学条件,试剂浓度和物理变量。该方法已用于测定废水中的正磷酸盐以及饮料和含有高浓度目标分析物的生物样品。已选择采用电还原和钼蓝经典分光光度分批方法以及电感耦合等离子体-光发射光谱法检测的已开发顺序进样系统的装置的t检验比较方法显示,在95%置信水平下,没有证据表明所得结果之间存在显着差异。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号