首页> 外文期刊>Advanced Optical Technologies >Hyperspectral data acquisition and analysis in imaging and real-time active MIR backscattering spectroscopy
【24h】

Hyperspectral data acquisition and analysis in imaging and real-time active MIR backscattering spectroscopy

机译:高光谱数据采集与成像和实时活性MIR反向散射光谱的分析

获取原文
获取原文并翻译 | 示例
       

摘要

In this work we present data analysis algorithms for detection of hazardous substances in hyperspectral observations acquired using active mid-infrared (MIR) backscattering spectroscopy. We present a novel background extraction algorithm based on the adaptive target generation process proposed by Ren and Chang called the adaptive background generation process (ABGP) that generates a robust and physically meaningful set of background spectra for operation of the well-known adaptive matched subspace detection (AMSD) algorithm. It is shown that the resulting AMSD-ABGP detection algorithm competes well with other widely used detection algorithms. The method is demonstrated in measurement data obtained by two fundamentally different active MIR hyperspectral data acquisition devices. A hyperspectral image sensor applicable in static scenes takes a wavelength sequential approach to hyperspectral data acquisition, whereas a rapid wavelength-scanning single-element detector variant of the same principle uses spatial scanning to generate the hyperspectral observation. It is shown that the measurement timescale of the latter is sufficient for the application of the data analysis algorithms even in dynamic scenarios.
机译:None

著录项

  • 来源
    《Advanced Optical Technologies》 |2017年第2期|共9页
  • 作者单位

    Fraunhofer Institute for Applied Solid State Physics (IAF) Tullastrasse 72 79108 Freiburg Germany;

    Fraunhofer Institute for Applied Solid State Physics (IAF) Freiburg Germany;

    Fraunhofer Institute for Applied Solid State Physics (IAF) Tullastrasse 72 79108 Freiburg Germany;

    Fraunhofer Institute for Applied Solid State Physics (IAF) Tullastrasse 72 79108 Freiburg Germany;

    Fraunhofer Institute for Applied Solid State Physics (IAF) Tullastrasse 72 79108 Freiburg Germany;

    Fraunhofer Institute for Applied Solid State Physics (IAF) Tullastrasse 72 79108 Freiburg Germany;

    Fraunhofer Institute for Applied Solid State Physics (IAF) Tullastrasse 72 79108 Freiburg Germany;

    Fraunhofer Institute of Optronics System Technologies and Image Exploitation (IOSB) Karlsruhe Institute of Technologie (KIT) Karlsruhe Germany;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 光学;
  • 关键词

    active stand-off spectroscopy; hyperspectral data analysis; QCL;

    机译:有源脱扣光谱;高光谱数据分析;QCL;