首页> 外文期刊>Analytica chimica acta >Low volume microwave digestion for the determination of selenium in marine biological tissues by graphite furnace atomic absorption spectroscopy
【24h】

Low volume microwave digestion for the determination of selenium in marine biological tissues by graphite furnace atomic absorption spectroscopy

机译:小体积微波消解-石墨炉原子吸收光谱法测定海洋生物组织中的硒

获取原文
获取原文并翻译 | 示例
           

摘要

A microwave digestion method for the determination of marine biological tissues has been developed to allow determination of selenium in small sample sizes (< 0.1 g). The benefits of this technique include maintaining concentrates in extracts without the subsequent over dilution encountered when using larger vessels, increased sample throughput and reduced loss of volatile material. Freeze dried biological material (< 0.1 g) and nitric acid (1 mi) were placed into 7 mi screw top Teflon vessels which are completely sealed on capping. Two 7 mi vials were placed into larger 120 mi vessels fitted with a Teflon spacer and 10 mi of distilled water. The effects of microwave power and time, and sample mass on selenium recovery from three marine standard reference materials (NIST SRM 1566a Oyster Tissue, NRCC DORM-1 Dogfish Muscle and NRCC TORT-1 Lobster Hepatopancreas) were examined. The optimum conditions: 600 W, 2 min; 0 W, 2 min; 450 W, 45 min, allowed quantitative recoveries of selenium from these and three other standard reference materials (NRCC DOLT-1 Dogfish liver, NIST RM-50 Albacore tuna and IAEA MA-A-2 fish flesh). Studies on sample mass showed that the analysis of sample masses from 0.025 to 0.1 g gave selenium concentrations within the certified range. Six species of selenium: selenite, selenate, selenomethionine, selenocysteine, selenocystamine, and trimethyl selenonium were added to oyster, dogfish, and lobster tissues. Recoveries were near quantitative for all species (94-105%) except trimethyl selenonium (90-101%).
机译:已经开发了一种用于测定海洋生物组织的微波消解方法,以测定小样本量(<0.1 g)中的硒。该技术的好处包括保持浓缩物在提取物中,而不会在使用较大的容器时出现随后的过度稀释,增加样品通量和减少挥发性物质损失的情况。将冷冻干燥的生物材料(<0.1 g)和硝酸(1 mi)放入7 mi螺旋顶特氟隆容器中,该容器在加盖时完全密封。将两个7毫升的小瓶放入装有Teflon垫片和10毫升蒸馏水的120毫升较大的容器中。考察了微波功率,时间和样品质量对三种海洋标准参考物质(NIST SRM 1566a牡蛎组织,NRCC DORM-1狗鱼肌肉和NRCC TORT-1龙虾肝胰腺)中硒的回收率的影响。最佳条件:600 W,2分钟; 0 W,2分钟; 450 W,45分钟,允许从这些和其他三种标准参考物质(NRCC DOLT-1 fish鱼肝,NIST RM-50长鳍金枪鱼和IAEA MA-A-2鱼肉)中定量回收硒。对样品质量的研究表明,对0.025至0.1 g的样品质量进行分析得出的硒浓度在认证范围内。将六种硒:亚硒酸盐,硒酸盐,硒代蛋氨酸,硒代半胱氨酸,硒代半胱胺和三甲基硒化物添加到牡蛎,dog鱼和龙虾组织中。除三甲基硒(90-101%)外,所有物种(94-105%)的回收率均接近定量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号