首页> 外文期刊>Analytica chimica acta >ON-LINE MONITORING OF TRACE AMOUNTS OF COPPER(II) IN STEAM CONDENSATE AND BOILER FEED-WATER BY FLOW INJECTION ANALYSIS BASED ON ITS CATALYTIC EFFECT ON THE OXIDATION OF HYDROQUINONE BY HYDROGEN PEROXIDE
【24h】

ON-LINE MONITORING OF TRACE AMOUNTS OF COPPER(II) IN STEAM CONDENSATE AND BOILER FEED-WATER BY FLOW INJECTION ANALYSIS BASED ON ITS CATALYTIC EFFECT ON THE OXIDATION OF HYDROQUINONE BY HYDROGEN PEROXIDE

机译:基于过氧化氢氧化氢醌催化作用的流动注射在线监测蒸汽冷凝水和锅炉给水中痕量铜(II)

获取原文
获取原文并翻译 | 示例
           

摘要

A flow injection analysis (FIA) method for on-line monitoring of trace amounts of copper(II) in steam condensate and boiler feed-water is described. This method is based on the catalytic effect of copper(II) on the oxidation of hydroquinone by hydrogen peroxide, the quinone produced being detected using UV-absorption at 490 nm. The effects of pH, temperature, the concentrations of hydroquinone and hydrogen peroxide, and reaction time on the determination of the selectivity and the sensitivity of this method were investigated. An FIA-kinetic determination method with both high selectivity and sensitivity was obtained by the optimization of the detection conditions. Trace amounts of copper(II) in steam condensate and boiler feed-water in power stations were successfully analyzed on-line using this method. [References: 15]
机译:描述了一种用于在线监测蒸汽冷凝水和锅炉给水中痕量铜(II)的流动注射分析(FIA)方法。该方法基于铜(II)对过氧化氢氧化氢醌的催化作用,使用490 nm的紫外线吸收检测生成的醌。研究了pH,温度,对苯二酚和过氧化氢的浓度以及反应时间对该方法的选择性和灵敏度的测定的影响。通过优化检测条件,获得了同时具有高选择性和高灵敏度的FIA动力学测定方法。该方法在线成功地分析了电厂蒸汽冷凝水和锅炉给水中的痕量铜(II)。 [参考:15]