Flow-Injection Analysis Based on Extraction and Spectrophotometric Determination of Penicillins with Thiazine Dyes

机译:噻嗪染料萃取-分光光度法测定流动注射分析

获取原文
获取原文并翻译 | 示例

摘要

A new method for flow-injection analysis (FIA) for the determination of penicillins based on the extraction and spectrophotometric determination of ion associates with selected thiazine dyes (methylene blue, azure A, and azure B) is proposed. The reaction conditions (c_(dye)=2 × 10~(-4) moll~(-1), c_(Kcl) = 1 moll~(-1), pH ≌ 6, λ= 635 nm) were found. The factorial design has been carried out to determine the optimum flow conditions. A wide linear dynamic range of calibration curves (5.1-700 μ g ml~(-1) for penicillin V with all dyes, R = 0.9985) and good repeatability (e.g., relative standard deviation [RSD] = 4.6-0.6% in this concentration range for the reaction with azure B) were found. The detection limit for penicillin V is 1.5μgml~(-1), and the determination limit is 5.1 μ g ml~(-1). The maxi-mum analysis rate is 35 samples per h. The practical samples of pharmaceutics were tested. There are no interferences from the additives in pharmaceutics.
机译:提出了一种基于选择性噻嗪染料(亚甲基蓝,天蓝色A和天蓝色B)的离子缔合物的萃取和分光光度法测定青霉素的流动注射分析(FIA)新方法。确定了反应条件(c_(染料)= 2×10〜(-4)moll〜(-1),c_(Kcl)= 1 moll〜(-1),pH≥6,λ= 635 nm)。已进行析因设计以确定最佳流动条件。校准曲线的线性动态范围宽(对于所有染料,青霉素V的校准曲线为5.1-700μg ml〜(-1),R = 0.9985),重复性好(例如,相对标准偏差[RSD] = 4.6-0.6%)发现与天青B)反应的浓度范围。青霉素V的检出限为1.5μgml〜(-1),测定限为5.1μgml〜(-1)。最大分析速率为每小时35个样品。测试了药物的实际样品。药物中的添加剂不会产生干扰。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号