A fast spectrometric kinetic method for mercury(II) ions determination based on their property to inhibit glucose-oxidase activity is presented. The measurement of enzyme activity was based on enzymatic reduction of benzoquinone to hydroquinone and on the measurements of the initial rate of hydroquinone absorbance increase at 290 nm. A calibration curve for Hg(II) concentrations was obtained in the 0.05-1.0 mu;g/mL range, with a detection limit of 0.015 mu;g/mL and a relative standard deviation RSD ≤2.7%. The analysis time was 2 min. Determination of mercury in a real sample was in good agreement with the declared mercury concentration.
机译:提出了一种基于汞离子抑制葡萄糖氧化酶活性的快速动力学动力学测定汞离子的方法。酶活性的测定是基于将苯醌酶促还原为对苯二酚和对苯二酚在290 nm处吸光度的初始增加速率的测量。 Hg(II)浓度的校准曲线在0.05-1.0μg/ mL范围内获得,检出限为0.015μg/ mL,相对标准偏差RSD≤2.7%。分析时间为2分钟。实际样品中汞的测定与宣布的汞浓度高度吻合。