An amperometric biosensor for the determination of L-lactic acid in probiotic yogurts has been assembled using L-lactate dehydrogenase (EC 1.1.1.27, LDH) entrapped in 1% (v/v) neutralized Nafion~? solution deposited on Variamine blue redox mediator modified screen-printed electrodes. The Variamine blue was previously covalently linked to oxidized single-walled carbon nanotubes and used for modifying screen-printed electrodes. The electrochemical cell, containing the L-lactate biosensor operating at an applied working potential of +200 mV vs. Ag{pipe}AgCl, was coupled with a microdialysis fiber and connected with a flow system, thus obtaining a microdialysis based sampling experimental set-up. Various analytical parameters, such as the cofactor concentration (2 mM, NAD~+), the flow rate (10.5 μL/min), the applied working potential (+200 mV vs. Ag{pipe}AgCl), the working buffer (50 mM phosphate buffer 0.1 M KCl), and pH (7.5), were optimized in batch amperometric experiments. The dynamic linear working range was comprised between 2 · 10~(-4) and 1 · 10~(-3) M. The proposed biosensor was challenged with real samples of yogurt, properly diluted in working buffer, and the performances of the L-lactate biosensor were compared with a commercially available kit for the determination of L-lactic acid in foodstuffs from R-Biopharm GmbH, Germany, showing a good agreement.
机译:已使用包裹在1%(v / v)中和的Nafion中的L-乳酸脱氢酶(EC 1.1.1.27,LDH)组装了用于测定益生菌酸奶中L-乳酸的安培生物传感器。溶液沉积在Variamine蓝色氧化还原介体修饰的丝网印刷电极上。缬胺蓝预先与氧化的单壁碳纳米管共价连接,并用于修饰丝网印刷电极。电化学电池包含L-乳酸生物传感器,其工作电压为+200 mV(相对于Ag {pipe} AgCl),与微透析纤维耦合并与流动系统连接,从而获得基于微透析的采样实验装置,向上。各种分析参数,例如辅因子浓度(2 mM,NAD〜+),流速(10.5μL/ min),施加的工作电位(+200 mV对Ag {pipe} AgCl),工作缓冲液(50在批量安培实验中优化了mM磷酸盐缓冲液(0.1 M KCl)和pH(7.5)。动态线性工作范围介于2·10〜(-4)和1·10〜(-3)M之间。拟议的生物传感器受到酸奶的真实样品的挑战,并在工作缓冲液中适当稀释,并且L的性能将乳酸生物传感器与可商购的试剂盒(德国R-Biopharm GmbH,用于测定食品中的L-乳酸)进行了比较,显示出很好的一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号